Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/108885
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLahor i Soler, Eduard-
dc.contributor.authorMiranda i Rius, Jaume-
dc.contributor.authorBrunet i Llobet, Lluís-
dc.contributor.authorSabaté, Xavier, 1950--
dc.date.accessioned2017-03-24T12:54:12Z-
dc.date.available2017-06-30T22:01:28Z-
dc.date.issued2015-06-
dc.identifier.issn0909-8836-
dc.identifier.urihttp://hdl.handle.net/2445/108885-
dc.description.abstractPatients with cardiac implantable electrical devices should take precautions when exposed to electromagnetic fields. Possible interference as a result of proximity to electromagnets or electricity flow from electronic tools employed in clinical odontology remains controversial. The objective of this study was to examine in vitro the capacity of dental equipment to provoke electromagnetic interference in pacemakers and implantable cardioverter defibrillators. Six electronic dental instruments were tested on three implantable cardioverter defibrillators and three pacemakers from different manufacturers. A simulator model, submerged in physiological saline, with elements that reproduced life-size anatomic structures was used. The instruments were analyzed at differing distances and for different time periods of application. The dental instruments studied displayed significant differences in their capacity to trigger electromagnetic interference. Significant differences in the quantity of registered interference were observed with respect to the variables manufacturer, type of cardiac implant, and application distance but not with the variable time of application. The electronic dental equipment tested at a clinical application distance (20 cm) provoked only slight interference in the pacemakers and implantable cardioverter defibrillators employed, irrespective of manufacturer.-
dc.format.extent8 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherWiley-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1111/eos.12183-
dc.relation.ispartofEuropean Journal of Oral Sciences, 2015, vol. 123, num. 3, p. 194-201-
dc.relation.urihttps://doi.org/10.1111/eos.12183-
dc.rights(c) European Journal of Oral Sciences, 2015-
dc.sourceArticles publicats en revistes (Odontoestomatologia)-
dc.subject.classificationAparells i instruments odontològics-
dc.subject.classificationCamps electromagnètics-
dc.subject.classificationInterferència electromagnètica-
dc.subject.classificationPolpa dental-
dc.subject.classificationAparells i instruments quirúrgics-
dc.subject.classificationImplants dentals-
dc.subject.classificationDesfibril·ladors cardioversors implantables-
dc.subject.otherDental instruments and apparatus-
dc.subject.otherElectromagnetic fields-
dc.subject.otherElectromagnetic interference-
dc.subject.otherDental pulp-
dc.subject.otherSurgical instruments and apparatus-
dc.subject.otherDental implants-
dc.subject.otherImplantable cardioverter-defibrillators-
dc.titleCapacity of dental equipment to interfere with cardiac implantable electrical devices-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec652820-
dc.date.updated2017-03-24T12:54:12Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid25913780-
Appears in Collections:Articles publicats en revistes (Odontoestomatologia)

Files in This Item:
File Description SizeFormat 
652820.pdf280.5 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.