Abstract: Duodenal perforations are a rare complication during interventional endoscopy. Their mortality is high, and the treatment in most cases is surgical. We report a case of duodenal perforation (type I, Stapfer) (1) during an interventional endoscopic ultrasound (EUS) procedure resolved using an over-the-scope clip called OTSC.
Note: Reproducció del document publicat a: https://doi.org/10.4321/S1130-01082012000900007