Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/128586
Title: Analysis of factors affecting the variability of a quantitative suspension bead array assay measuring IgG to multiple Plasmodium antigens
Author: Ubillos, Itziar
Aguilar, Ruth
Sanz Ródenas, Héctor
Jiménez, Alfons
Vidal, Marta
Valmaseda, Aida
Dong, Yan
Gaur, Deepak
Chitnis, Chetan E.
Dutta, Sheetij
Angov, Evelina
Aponte, John J.
Campo, Joseph J.
Valim, Clarissa
Harezlak, Jaroslaw
Dobaño, Carlota, 1969-
Keywords: Antígens
Plasmodium falciparum
Antigens
Issue Date: 2-Jul-2018
Publisher: Public Library of Science (PLoS)
Abstract: Reducing variability of quantitative suspension array assays is key for multi-center and large sero-epidemiological studies. To maximize precision and robustness of an in-house IgG multiplex assay, we analyzed the effect of several conditions on variability to find the best combination. The following assay conditions were studied through a fractional factorial design: antigen-bead coupling (stock vs. several), sample predilution (stock vs. daily), temperature of incubation of sample with antigen-bead (22°C vs. 37°C), plate washing (manual vs. automatic) and operator expertise (expert vs. apprentice). IgG levels against seven P. falciparum antigens with heterogeneous immunogenicities were measured in test samples, in a positive control and in blanks. We assessed the variability and MFI quantification range associated to each combination of conditions, and their interactions, and evaluated the minimum number of samples and blank replicates to achieve good replicability. Results showed that antigen immunogenicity and sample seroreactivity defined the optimal dilution to assess the effect of assay conditions on variability. We found that a unique antigen-bead coupling, samples prediluted daily, incubation at 22°C, and automatic washing, had lower variability. However, variability increased when performing several couplings and incubating at 22°C vs. 37°C. In addition, no effect of temperature was seen with a unique coupling. The expertise of the operator had no effect on assay variability but reduced the MFI quantification range. Finally, differences between sample replicates were minimal, and two blanks were sufficient to capture assay variability, as suggested by the constant Intraclass Correlation Coefficient of three and two blanks. To conclude, a single coupling was the variable that most consistently reduced assay variability, being clearly advisable. In addition, we suggest having more sample dilutions instead of replicates to increase the likelihood of sample MFIs falling in the linear part of the antigen-specific curve, thus increasing precision.
Note: Reproducció del document publicat a: http://dx.doi.org/ 10.1371/journal.pone.0199278
It is part of: PLoS One, 2018, vol. 13, num. 7, p. e0199278
URI: http://hdl.handle.net/2445/128586
Related resource: http://dx.doi.org/ 10.1371/journal.pone.0199278
ISSN: 1932-6203
Appears in Collections:Articles publicats en revistes (ISGlobal)

Files in This Item:
File Description SizeFormat 
Ubillos_PLoS_One_2018.pdf8.76 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons