Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/149147
Full metadata record
DC FieldValueLanguage
dc.contributor.authorReynés-Llompart, Gabriel-
dc.contributor.authorGámez Cenzano, Cristina-
dc.contributor.authorVercher Conejero, José Luís-
dc.contributor.authorSabaté Llobera, Aida-
dc.contributor.authorCalvo Malvar, Nahúm-
dc.contributor.authorMartí-Climent, Josep M.-
dc.date.accessioned2020-01-31T12:28:59Z-
dc.date.available2020-01-31T12:28:59Z-
dc.date.issued2018-06-08-
dc.identifier.issn0094-2405-
dc.identifier.urihttp://hdl.handle.net/2445/149147-
dc.description.abstractINTRODUCTION: The aim of this study was to evaluate the behavior of a penalized-likelihood image reconstruction method (Q.Clear) under different count statistics and lesion-to-background ratios (LBR) on a BGO scanner, in order to obtain an optimum penalization factor (β value) to study and optimize for different acquisition protocols and clinical goals. METHODS: Both phantom and patient images were evaluated. Data from an image quality phantom were acquired using different Lesion-to-Background ratios and acquisition times. Then, each series of the phantom was reconstructed using β values between 50 and 500, at intervals of 50. Hot and cold contrasts were obtained, as well as background variability and contrast-to-noise ratio (CNR). Fifteen 18 F-FDG patients (five brain scans and 10 torso acquisitions) were acquired and reconstructed using the same β values as in the phantom reconstructions. From each lesion in the torso acquisition, noise, contrast, and signal-to-noise ratio (SNR) were computed. Image quality was assessed by two different nuclear medicine physicians. Additionally, the behaviors of 12 different textural indices were studied over 20 different lesions. RESULTS: Q.Clear quantification and optimization in patient studies depends on the activity concentration as well as on the lesion size. In the studied range, an increase on β is translated in a decrease in lesion contrast and noise. The net product is an overall increase in the SNR, presenting a tendency to a steady value similar to the CNR in phantom data. As the activity concentration or the sphere size increase the optimal β increases, similar results are obtained from clinical data. From the subjective quality assessment, the optimal β value for torso scans is in a range between 300 and 400, and from 100 to 200 for brain scans. For the recommended torso β values, texture indices present coefficients of variation below 10%. CONCLUSIONS: Our phantom and patients demonstrate that improvement of CNR and SNR of Q.Clear algorithm which depends on the studied conditions and the penalization factor. Using the Q.Clear reconstruction algorithm in a BGO scanner, a β value of 350 and 200 appears to be the optimal value for 18F-FDG oncology and brain PET/CT, respectively.-
dc.format.extent9 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherAmerican Association of Physicists in Medicine-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1002/mp.12986-
dc.relation.ispartofMedical Physics, 2018, vol. 45, num. 7, p. 3214-3222-
dc.relation.urihttps://doi.org/10.1002/mp.12986-
dc.rights(c) American Association of Physicists in Medicine, 2018-
dc.sourceArticles publicats en revistes (Ciències Clíniques)-
dc.subject.classificationTomografia per emissió de positrons-
dc.subject.classificationTomografia computada per emissió de fotó simple-
dc.subject.classificationImatges mèdiques-
dc.subject.otherPositron emission tomography-
dc.subject.otherSingle-photon emission computed tomography-
dc.subject.otherImaging systems in medicine-
dc.titlePhantom, clinical, and texture indices evaluation and optimization of a penalized-likelihood image reconstruction method (Q.Clear) on a BGO PET/CT scanner-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec687560-
dc.date.updated2020-01-31T12:28:59Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
Articles publicats en revistes (Ciències Clíniques)

Files in This Item:
File Description SizeFormat 
687560.pdf683.47 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.