Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/151012
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEtxeberria Urra, Marina-
dc.contributor.authorEscuin Henar, Tomás J. (Tomás José)-
dc.contributor.authorViñas, Miquel-
dc.contributor.authorAscaso Terrén, Carlos-
dc.date.accessioned2020-02-21T14:27:41Z-
dc.date.available2020-02-21T14:27:41Z-
dc.date.issued2015-12-
dc.identifier.issn0161-0457-
dc.identifier.urihttp://hdl.handle.net/2445/151012-
dc.description.abstractTopographical features of biomaterials' surfaces are determinant when addressing their application site. Unfortunately up to date there has not been an agreement regarding which surface parameters are more representative in discriminating between materials. Discs (n = 16) of different currently used materials for implant prostheses fabrication, such as cast cobalt‐chrome, direct laser metal soldered (DLMS) cobalt‐chrome, titanium grade V, zirconia (Y‐TZP), E‐glass fiber‐reinforced composite and polyetheretherketone (PEEK) were manufactured. Nanoscale topographical surface roughness parameters generated by atomic force microscopy (AFM), microscale surface roughness parameters obtained by white light interferometry (WLI) and water angle values obtained by the sessile‐water‐drop method were analyzed in order to assess which parameter provides the best optimum surface characterization method. Correlations between nanoroughness, microroughness, and hydrophobicity data were performed to achieve the best parameters giving the highest discriminatory power. A subset of six parameters for surface characterization were proposed. AFM and WLI techniques gave complementary information. Wettability did not correlate with any of the nanoroughness parameters while it however showed a weak correlation with microroughness parameters.-
dc.format.extent9 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherWiley Hindawi Publishing-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1002/sca.21232-
dc.relation.ispartofScanning, 2015, vol. 37, num. 6, p. 429-437-
dc.relation.urihttps://doi.org/10.1002/sca.21232-
dc.rightscc-by (c) Etxeberria, Marina et al., 2015-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es-
dc.sourceArticles publicats en revistes (Patologia i Terapèutica Experimental)-
dc.subject.classificationMicroscòpia de força atòmica-
dc.subject.classificationBiometria-
dc.subject.classificationInterferometria-
dc.subject.otherAtomic force microscopy-
dc.subject.otherBiometry-
dc.subject.otherInterferometry-
dc.titleUseful surface parameters for biomaterial discrimination-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec654447-
dc.date.updated2020-02-21T14:27:41Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Patologia i Terapèutica Experimental)
Articles publicats en revistes (Fonaments Clínics)

Files in This Item:
File Description SizeFormat 
654447.pdf174.1 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons