Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/159770
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRuiz García, Marta-
dc.contributor.authorPérez Lozano, Pilar-
dc.contributor.authorMercadé Frutos, Débora-
dc.contributor.authorNardi Ricart, Anna-
dc.contributor.authorSuñé Pou, Marc-
dc.contributor.authorCano Sarabia, Mary-
dc.contributor.authorGarcía Jimeno, Sonia-
dc.contributor.authorSuñé i Negre, Josep M. (Josep Maria)-
dc.contributor.authorMaspoch, Daniel-
dc.contributor.authorGarcía Montoya, Encarna-
dc.date.accessioned2020-05-12T14:06:09Z-
dc.date.available2020-05-12T14:06:09Z-
dc.date.issued2019-11-26-
dc.identifier.issn2470-1343-
dc.identifier.urihttp://hdl.handle.net/2445/159770-
dc.description.abstractA high-performance liquid chromatography (HPLC) method was developed to simultaneously quantify three widely used active substances such as coenzyme Q10, phosphatidylserine, and vitamin C. This new method optimizes current timing and costs in the analyses of these three active substances. Additionally, since the analyzed compounds were encapsulated on a cutting-edge liposomal formulation, further processing was necessary to be developed prior to HPLC analyses. The technique was studied and adequately validated in accordance with the guidelines of the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) regarding selectivity, linearity, accuracy, precision, and robustness. After data treatment of results, linear regressions for all active substances showed an optimal linearity with a correlation coefficient of >0.999 in the concentration range between 70 to 130% of the liposomal formulation and less than a 3% relative standard deviation (RSD) in accuracy and precision.-
dc.format.extent6 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherAmerican Chemical Society-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1021/acsomega.9b02456-
dc.relation.ispartofACS Omega , 2019, vol. 4, num. 22, p. 19710-19715-
dc.relation.urihttps://doi.org/10.1021/acsomega.9b02456-
dc.rights(c) American Chemical Society, 2019-
dc.sourceArticles publicats en revistes (Farmàcia, Tecnologia Farmacèutica i Fisicoquímica)-
dc.subject.classificationCromatografia de líquids-
dc.subject.classificationCoenzims-
dc.subject.otherLiquid chromatography-
dc.subject.otherCoenzymes-
dc.titleDevelopment and Validation of a New High-Performance Liquid Chromatography Method for the Simultaneous Quantification of Coenzyme Q10, Phosphatidylserine, and Vitamin C from a Cutting-Edge Liposomal Vehiculization-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec694683-
dc.date.updated2020-05-12T14:06:09Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid31788602-
Appears in Collections:Articles publicats en revistes (Farmàcia, Tecnologia Farmacèutica i Fisicoquímica)
Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
694683.pdf920.62 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.