dc.contributor.authorAvila, Claudio R.-
dc.contributor.authorFerré, Joan-
dc.contributor.authorRocha de Oliveira, Rodrigo-
dc.contributor.authorJuan Capdevila, Anna de-
dc.contributor.authorSinclair, Wayne E.-
dc.contributor.authorMahdi, Faiz M.-
dc.contributor.authorHassanpour, Ali-
dc.contributor.authorHunter, Timothy N.-
dc.contributor.authorBourne, Richard A.-
dc.contributor.authorMuller, Frans L.-
dc.date.accessioned2020-10-05T09:21:01Z-
dc.date.available2020-10-05T09:21:01Z-
dc.date.issued2020-04-21-
dc.identifier.issn0724-8741-
dc.identifier.urihttp://hdl.handle.net/2445/170959-
dc.description.abstractPurpose The current trend for continuous drug product manufacturing requires new, affordable process analytical techniques (PAT) to ensure control of processing. This work evaluates whether property models based on spectral data from recent Fabry-Pérot Interferometer based NIR sensors can generate a high-resolution moisture signal suitable for process control. Methods Spectral data and offline moisture content were recorded for 14 fluid bed dryer batches of pharmaceutical granules. A PLS moisture model was constructed resulting in a high resolution moisture signal, used to demonstrate (i) endpoint determination and (ii) evaluation of mass transfer performance. Results The sensors appear robust with respect to vibration and ambient temperature changes, and the accuracy of water content predictions (±13%) is similar to those reported for high specification NIR sensors. Fusion of temperature and moisture content signal allowed monitoring of water transport rates in the fluidised bed and highlighted the importance water transport within the solid phase at low moisture levels. The NIR data was also successfully used with PCA-based MSPC models for endpoint detection. Conclusions The spectral quality of the small form factor NIR sensor and its robustness is clearly sufficient for the construction and application of PLS models as well as PCA-based MSPC moisture models. The resulting high resolution moisture content signal was successfully used for endpoint detection and monitoring the mass transfer rate.-
dc.format.extent19 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherSpringer Science + Business Media-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1007/s11095-020-02787-y-
dc.relation.ispartofPharmaceutical Research, 2020, vol. 37-
dc.relation.urihttps://doi.org/10.1007/s11095-020-02787-y-
dc.rightscc by (c) Avila et al., 2020-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationFluids-
dc.subject.classificationEspectrometria de masses-
dc.subject.otherFluids-
dc.subject.otherMass spectrometry-
dc.titleProcess monitoring of moisture content and mass transfer rate in a fluidised bed with a low cost inline MEMS NIR sensor-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec700478-
dc.date.updated2020-10-05T09:21:01Z-
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/637232/EU//ProPAT-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid32318827-
Appears in Collections:Articles publicats en revistes (Enginyeria Química i Química Analítica)

Files in This Item:
File Description SizeFormat 
700478.pdf4.35 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons