dc.contributor.authorCastelo-Branco Flores, Camil-
dc.contributor.authorDuro Gómez, Jorge-
dc.contributor.authorRomero Dominguez, Marina-
dc.contributor.authorRodríguez Marín, Ana Belén-
dc.contributor.authorPovedano Canizares, Balbino-
dc.contributor.authorNaumova, Iuliia-
dc.date.accessioned2020-11-12T17:13:02Z-
dc.date.available2020-11-12T17:13:02Z-
dc.date.issued2019-04-01-
dc.identifier.issn2652-466X-
dc.identifier.urihttp://hdl.handle.net/2445/172035-
dc.description.abstractObjective: To analyse the reasons for Essure® removal in a large cohort of patients. Design: Retrospective 15-year study. Setting: Office hysteroscopy unit in a teaching hospital. Methods: From 2003 to 2015, 8024 Essure® device insertions were performed in a single centre in Córdoba (Spain). Of these, 156 patients (1.89%) presented adverse events requiring device withdrawal (SG) A subset of 156 women matched for age, clinical characteristics and time since insertion were used for case-control comparisons (CG). In 47 cases, the device had already been surgically removed. Three months later, patients were questioned regarding symptoms and their general condition. Main Outcome Measure(s): Pre and post-operative adverse events, early postoperative and late complications (after the initial 3 months) and patients' satisfaction after procedures. Results: In the SG, 23.08% (36) of the patients were allergic to nickel compared to only 1.28% (2) in the CG (p<0.01). No differences were found in insertion difficulty or pain or related to the time with the device. Surprisingly, satisfaction was higher at 3 months in the SG compared to the CG (100% vs. 90.90 %, respectively (p=0.01)). Currently, 58.61% (93) of the SG and 1.28 % (2) of the CG report pelvic pain as the most bother some symptom (p<0.01). The SG described abundant menstrual bleeding, allergy, asthenia, polyarthralgia and urinary tract infection. Of the 47 patients who had already undergone surgical device removal, 78.72% (37) reporting feeling well/very well, and 85.10% (40) felt better than before surgery. However, up to 93.67% (43) still had some complaints. Conclusion: Appropriate patient selection and careful preoperative assessment are required. Women should be informed about the benefits and risks of hysteroscopy and traditional sterilisation.-
dc.format.extent6 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherGRF Publishers-
dc.relation.isformatofReproducció del document publicat a: https://grfpublishers.com/article/view/NDc=/Essure-Attributed-Symptoms-Follow-up-of-a-Large-Cohort-after-Device-Removal-A-Retrospective-Nested-Case-Co-
dc.relation.ispartofJournal of Obstetrics and Gynecological Problems, 2019, vol. 2019, num. JOGP-100002 (1), p. 1-6-
dc.rightscc-by (c) Castelo-Branco Flores, Camil et al., 2019-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es-
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)-
dc.subject.classificationContracepció-
dc.subject.classificationComplicacions quirúrgiques-
dc.subject.otherContraception-
dc.subject.otherComplications of surgery-
dc.titleEssure-Attributed Symptoms: Follow-up of a Large Cohort after Device Removal: A Retrospective Nested Case-Control Study-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec704292-
dc.date.updated2020-11-12T17:13:02Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)

Files in This Item:
File Description SizeFormat 
704292.pdf636.58 kBAdobe PDFView/Open