Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/173106
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPérez-Alcaraz, Albert-
dc.contributor.authorBorrull, Francesc-
dc.contributor.authorAguilar, Carme-
dc.contributor.authorCalull, Marta-
dc.contributor.authorBenavente Moreno, Fernando J. (Julián)-
dc.date.accessioned2021-01-18T10:27:18Z-
dc.date.available2022-12-14T06:10:27Z-
dc.date.issued2020-12-14-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://hdl.handle.net/2445/173106-
dc.description.abstractThis study presents for the first time an in-line solid-phase extraction capillary electrophoresis-mass spectrometry (SPE-CE-MS) method for the enantiodetermination of drugs of abuse in urine samples. The enantioseparation of R,S-3,4-methylenedioxypyrovalerone (R,S-MDPV) was achieved with a 10 mM ammonium acetate BGE (pH 7) that contained 0.5% (m/v) of sulphated-α-CD as chiral selector. At these pH conditions, this CD was negatively charged, which prevented its entrance into the mass spectrometer since it migrates in the opposite direction. To improve sensitivity, an in-line SPE-CE-MS method using high pressure for sample introduction (i.e. 20 min at 3 bars) was developed. Furthermore, the conditioning procedure and the first part of the electrophoretic separation were performed by switching off the nebulizer gas and the ionization source voltage to avoid non-volatile contaminant arrival into the mass spectrometer. The developed methodology was validated by analyzing urine samples, which required a very simple liquid-liquid extraction (LLE) sample pretreatment. Linearity ranged from 30 to 250 ng/mL, limit of detection (LOD) was 10 ng/mL, relative standard deviation (RSD) values were below 10.5% in terms of intra-day and inter-day precision and the relative error values were below 9% for peak areas accuracy.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2020.121994-
dc.relation.ispartofTalanta, 2020, vol. 225, p. 121994-
dc.relation.urihttps://doi.org/10.1016/j.talanta.2020.121994-
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2020-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationEspectrometria de masses-
dc.subject.classificationElectroforesi capil·lar-
dc.subject.classificationAnàlisi d'orina-
dc.subject.otherMass spectrometry-
dc.subject.otherCapillary electrophoresis-
dc.subject.otherUrine analysis-
dc.titleEnantiodetermination of R,S-3,4-methylenedioxypyrovalerone in urine samples by high pressure in-line solid-phase extraction capillary electrophoresis-mass spectrometry-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec704991-
dc.date.updated2021-01-18T10:27:18Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Enginyeria Química i Química Analítica)

Files in This Item:
File Description SizeFormat 
704991.pdf999.82 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons