Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/190825
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPujol-López, Margarida-
dc.contributor.authorJiménez Arjona, Rafael-
dc.contributor.authorGuasch i Casany, Eduard-
dc.contributor.authorDoltra, Adelina-
dc.contributor.authorBorràs, Roger-
dc.contributor.authorRoca Luque, Ivo-
dc.contributor.authorCastel, María Ángeles-
dc.contributor.authorGarre, Paz-
dc.contributor.authorFerró, Elisenda-
dc.contributor.authorNiebla Bellido, Mireia-
dc.contributor.authorCarro, Esther-
dc.contributor.authorArbelo, Elena-
dc.contributor.authorSitges Carreño, Marta-
dc.contributor.authorTolosana, José M. (José María)-
dc.contributor.authorMont Girbau, Lluís-
dc.date.accessioned2022-11-15T17:39:43Z-
dc.date.available2022-11-15T17:39:43Z-
dc.date.issued2022-01-29-
dc.identifier.issn0147-8389-
dc.identifier.urihttp://hdl.handle.net/2445/190825-
dc.description.abstractBackground: His-Purkinje conduction system pacing (HPCSP) has been proposed as an alternative to Cardiac Resynchronization Therapy (CRT); however, predictors of echocardiographic response have not been described in this population. Septal flash (SF), a fast contraction and relaxation of the septum, is a marker of intraventricular dyssynchrony. Methods: The study aimed to analyze whether HPCSP corrects SF in patients with CRT indication, and if correction of SF predicts echocardiographic response. This retrospective analysis of prospectively collected data included 30 patients. Left ventricular ejection fraction (LVEF) was measured with echocardiography at baseline and at 6-month follow-up. Echocardiographic response was defined as increase in five points in LVEF. Results: HPCSP shortened QRS duration by 48 ± 21 ms and SF was significantly decreased (baseline 3.6 ± 2.2 mm vs. HPCSP 1.5 ± 1.5 mm p < .0001). At 6-month follow-up, mean LVEF improvement was 8.6% ± 8.7% and 64% of patients were responders. There was a significant correlation between SF correction and increased LVEF (r = .61, p = .004). A correction of ≥1.5 mm (baseline SF - paced SF) had a sensitivity of 81% and 80% specificity to predict echocardiographic response (area under the curve 0.856, p = .019). Conclusion: HPCSP improves intraventricular dyssynchrony and results in 64% echocardiographic responders at 6-month follow-up. Dyssynchrony improvement with SF correction may predict echocardiographic response at 6-month follow-up.-
dc.format.extent10 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherWiley-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1111/pace.14445-
dc.relation.ispartofPace-Pacing and Clinical Electrophysiology, 2022, vol. 45, num. 3, p. 374-383-
dc.relation.urihttps://doi.org/10.1111/pace.14445-
dc.rightscc-by-nc (c) Pujol-López, Margarida et al., 2022-
dc.rights.urihttp://creativecommons.org/licenses/by-nc/3.0/es/*
dc.sourceArticles publicats en revistes (Medicina)-
dc.subject.classificationEcocardiografia-
dc.subject.classificationInsuficiència cardíaca-
dc.subject.classificationVentricles cardíacs-
dc.subject.classificationMarcapassos-
dc.subject.otherEchocardiography-
dc.subject.otherHeart failure-
dc.subject.otherVentricle of heart-
dc.subject.otherCardiac pacemakers-
dc.titleSeptal Flash Correction with His-Purkinje Pacing Predicts Echocardiographic Response in Patients with Indication for Resynchronization Therapy-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec722193-
dc.date.updated2022-11-15T17:39:43Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid35015308-
Appears in Collections:Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)
Articles publicats en revistes (Medicina)

Files in This Item:
File Description SizeFormat 
722193.pdf6.04 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons