dc.dateDual energy x ray absorptiometry (DXA) is the most commonly used method of measuring bone mineral density (BMD); it has been shown to be a good predictor of the future risk of fracture.1Unfortunately, the generalised use of DXA is limited as it is expensive and time consuming, is not portable, and is available only in specialised clinics.#N##N#Computed digital absorptiometry (CDA) of the hand is a new bone densitometry technique, designed to assess the BMD of the middle phalanx of the third finger using a direct, automated measurement of x ray attenuation.2This technique is similar to radiographic absorptiometry but provides immediate results; in current radiographic absorptiometry, radiographs are sent to an off site processing centre and the results are received a few days later. CDA is cheap and quick. Its precision and accuracy seem to be acceptable, but its ability to discriminate between patients with osteoporosis and normal subjects, to predict risk of …-
dc.date.accessioned2012-03-05T12:52:33Z-
dc.date.available2012-03-05T12:52:33Z-
dc.date.issued2000ca
dc.identifier.issn0003-4967ca
dc.identifier.urihttp://hdl.handle.net/2445/22472-
dc.description.abstractDual energy x ray absorptiometry (DXA) is the most commonly used method of measuring bone mineral density (BMD); it has been shown to be a good predictor of the future risk of fracture.1Unfortunately, the generalised use of DXA is limited as it is expensive and time consuming, is not portable, and is available only in specialised clinics.#N##N#Computed digital absorptiometry (CDA) of the hand is a new bone densitometry technique, designed to assess the BMD of the middle phalanx of the third finger using a direct, automated measurement of x ray attenuation.2This technique is similar to radiographic absorptiometry but provides immediate results; in current radiographic absorptiometry, radiographs are sent to an off site processing centre and the results are received a few days later. CDA is cheap and quick. Its precision and accuracy seem to be acceptable, but its ability to discriminate between patients with osteoporosis and normal subjects, to predict risk of …-
dc.format.extent1 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoengeng
dc.publisherBMJ Group-
dc.relation.isformatofReproducció digital del document publicat a: http://dx.doi.org/10.1136/ard.59.6.490b-
dc.relation.ispartofAnnals of the Rheumatic Diseases, 2000, vol. 59, núm. 6, p. 492-
dc.relation.urihttp://dx.doi.org/10.1136/ard.59.6.490b-
dc.rights(c) BMJ Publishing Group Ltd, 2000-
dc.sourceArticles publicats en revistes (Ciències Clíniques)-
dc.subject.classificationDensitometria òssiacat
dc.subject.classificationArtritis reumatoidecat
dc.subject.classificationMenopausacat
dc.subject.otherBone densitometryeng
dc.subject.otherRheumatoid arthritiseng
dc.subject.otherMenopauseeng
dc.titleComputed digital absorptiometry of the hand: screening method of bone loss in postmenopausal women with RA.eng
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec535337ca
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid10885977-
Appears in Collections:Articles publicats en revistes (Ciències Clíniques)

Files in This Item:
File Description SizeFormat 
535337.pdf97.16 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.