dc.description.abstractIntravascular brachytherapy with beta sources has become a useful technique to prevent restenosis after cardiovascular intervention. In particular, the Beta-Cath high-dose-rate system, manufactured by Novoste Corporation, is a commercially available 90Sr 90Y source for intravascular brachytherapy that is achieving widespread use. Its dosimetric characterization has attracted considerable attention in recent years. Unfortunately, the short ranges of the emitted beta particles and the associated large dose gradients make experimental measurements particularly difficult. This circumstance has motivated the appearance of a number of papers addressing the characterization of this source by means of Monte Carlo simulation techniques.eng
dc.format.extent2 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherThe American Association of Physicists in Medicine-
dc.relation.isformatofReproducció del document publicat a: http://dx.doi.org/10.1118/1.1510455-
dc.relation.ispartofMedical Physics, 2002, vol. 29, p. 2737-2738-
dc.relation.urihttp://dx.doi.org/10.1118/1.1510455-
dc.rights(c) The American Association of Physicists in Medicine, 2002-
dc.sourceArticles publicats en revistes (Física Quàntica i Astrofísica)-
dc.subject.classificationMètode de Montecarlo-
dc.subject.classificationAnisotropia-
dc.subject.classificationFísica mèdica-
dc.subject.classificationBraquiteràpia-
dc.subject.otherMontecarlo method-
dc.subject.otherAnisotropy-
dc.subject.otherMedical physics-
dc.subject.otherRadioisotope brachytherapy-
dc.titleRadial dose function of a 90Sr 90Y seed in water and A150: Comment on Calibration and characterization of beta-particle sources for intravascular brachytherapy-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec504251-
dc.date.updated2012-05-02T11:55:12Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Física Quàntica i Astrofísica)

Files in This Item:
File Description SizeFormat 
504251.pdf34.19 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.