dc.contributor.authorNavajas Navarro, Danielcat
dc.contributor.authorFarré Ventura, Ramoncat
dc.contributor.authorRotger i Estapé, Maria del Marcat
dc.contributor.authorPeslin, Renécat
dc.date.accessioned2009-06-17T08:40:18Z-
dc.date.available2009-06-17T08:40:18Z-
dc.date.issued1988cat
dc.identifier.issn0018-9294cat
dc.identifier.urihttp://hdl.handle.net/2445/8686-
dc.description.abstractThis paper presents a new respiratory impedance estimator to minimize the error due to breathing. Its practical reliability was evaluated in a simulation using realistic signals. These signals were generated by superposing pressure and flow records obtained in two conditions: 1) when applying forced oscillation to a resistance- inertance- elastance (RIE) mechanical model; 2) when healthy subjects breathed through the unexcited forced oscillation generator. Impedances computed (4-32 Hz) from the simulated signals with the new estimator resulted in a mean value which was scarcely biased by the added breathing (errors less than 1 percent in the mean R, I , and E ) and had a small variability (coefficients of variation of R, I, and E of 1.3, 3.5, and 9.6 percent, respectively). Our results suggest that the proposed estimator reduces the error in measurement of respiratory impedance without appreciable extracomputational cost.eng
dc.format.extent5 p.cat
dc.format.mimetypeapplication/pdfeng
dc.language.isoengeng
dc.publisherIEEEcat
dc.relation.isformatofReproducció del document publicat a http://dx.doi.org/10.1109/10.8684cat
dc.relation.ispartofIEEE Transactions on Biomedical Engineering, 1988, vol. 35, núm. 12, p. 1001-1005.eng
dc.relation.requireshttp://dx.doi.org/10.1109/10.8684-
dc.rights(c) IEEE, 1988eng
dc.sourceArticles publicats en revistes (Ciències Fisiològiques)-
dc.subject.classificationErrors científicscat
dc.subject.classificationMesuramentcat
dc.subject.otherBiomedical measurementeng
dc.subject.otherMeasurement errorseng
dc.subject.otherPneumodynamicseng
dc.titleA new estimator to minimize the error due to breathing in the measurement of respiratory impedanceeng
dc.typeinfo:eu-repo/semantics/articlecat
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec35251cat
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-