Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/98420
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLucci, Paolo-
dc.contributor.authorNúñez Burcio, Oscar-
dc.contributor.authorGalcerán Huguet, M. Teresa-
dc.date.accessioned2016-05-09T07:22:46Z-
dc.date.available2016-05-09T07:22:46Z-
dc.date.issued2011-02-13-
dc.identifier.issn0021-9673-
dc.identifier.urihttp://hdl.handle.net/2445/98420-
dc.description.abstractA method is proposed for the clean-up and preconcentration of natural and synthetic estrogens from aqueous samples employing molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE). The selectivity of the MIP was checked toward several selected natural and synthetic estrogens such as estrone (E1), 17β-estradiol (β-E2), 17α-estradiol (α-E2), estriol (E3), 17α-ethinylestradiol (EE2), dienestrol (DIES) and diethylstilbestrol (DES). Ultrahigh pressure liquid chromatography (UHPLC) coupled to a TSQ triple quadrupole mass spectrometry (QqQ) was used for analysis of target analytes. The chromatographic separation of the selected compounds was performed in less than 2 min under isocratic conditions. The method was applied to the analysis of estrogens in spiked river and tap water samples. High recoveries (>82%) for estrone, 17β-estradiol, 17α-estradiol, estriol and 17α-ethinylestradiol were obtained. Lower but still satisfactory recoveries (>48%) were achieved for dienestrol and diethylstilbestrol. The method was validated and found to be linear in the range 50-500 ng L-1 with correlation coefficients (R2) greater than 0.995 and repeatability relative standard deviation (RSD) below 8% in all cases. For analysis of 100-ml sample, the method detection limits (LOD) ranged from 4.5 to 9.8 ng L-1 and the limit of quantitation (LOQ) from 14.9 to 32.6 ng L-1. To demonstrate the potential of the MIP obtained, a comparison with commercially available C18 SPE was performed. Molecularly imprinted SPE showed higher recoveries than commercially available C18 SPE for most of the compounds. These results showed the suitability of the MIP-SPE method for the selective extraction of a class of structurally related compounds such as natural and synthetic estrogens.-
dc.format.extent6 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.relation.isformatofVersió postprint del document publicat a: http://dx.doi.org/10.1016/j.chroma.2011.02.007-
dc.relation.ispartofJournal of Chromatography A, 2011, vol. 1218, num. 30, p. 4828-4833-
dc.relation.urihttp://dx.doi.org/10.1016/j.chroma.2011.02.007-
dc.rights(c) Elsevier B.V., 2011-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationEstrògens-
dc.subject.classificationCromatografia de líquids d'alta resolució-
dc.subject.classificationEspectrometria de masses-
dc.subject.otherEstrogen-
dc.subject.otherHigh performance liquid chromatography-
dc.subject.otherMass spectrometry-
dc.titleSolid-phase extraction using molecularly imprinted polymer for selective extraction of natural and syntetic estrogens from aqueous samples-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec596565-
dc.date.updated2016-05-09T07:22:51Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid21356538-
Appears in Collections:Articles publicats en revistes (Enginyeria Química i Química Analítica)

Files in This Item:
File Description SizeFormat 
596565.pdf567.45 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.