Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/98431
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSeró Llor, Raquel-
dc.contributor.authorNúñez Burcio, Oscar-
dc.contributor.authorBosch i Genover, Jaume-
dc.contributor.authorGrases, Josep M.-
dc.contributor.authorRodríguez, Pilar-
dc.contributor.authorMoyano Morcillo, Encarnación-
dc.contributor.authorGalcerán Huguet, M. Teresa-
dc.date.accessioned2016-05-09T09:31:28Z-
dc.date.available2016-07-14T22:01:21Z-
dc.date.issued2015-07-14-
dc.identifier.issn1618-2642-
dc.identifier.urihttp://hdl.handle.net/2445/98431-
dc.description.abstractIn this study, a desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) screening method was developed for fast identification of veterinary drugs in cross-contaminated feedstuffs. The reliable detection was performed working at high resolution (70,000 full with half maximum, FWHM) using an orbitrap mass analyser. Among the optimized DESI parameters, the solvent (acetonitrile-water, 80:20, v/v) and the sample substrate (poly-tetrafluoroethylene, PTFE) were critical to obtain the best sensitivity. To analyse the solid feed samples, different approaches were tested and a simple solid-liquid extraction and the direct analysis of an aliquot (2 μL) of the extract after let it dry on the PTFE printed spot provided the best results. The identification of the veterinary drugs (target and non-target) in the cross-contaminated feedstuffs based on the accurate mass measurement and the isotopic pattern fit was performed automatically using a custom-made database. The positive crosscontaminated feed samples were quantified by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The results obtained demonstrate that DESI-HRMS can be proposed as a fast and suitable screening method to identify positive cross-contaminated feedstuffs reducing the number of samples to be subsequently quantified by UHPLC-MS/MS thus improving the productivity in quality control laboratories.-
dc.format.extent10 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherSpringer Verlag-
dc.relation.isformatofVersió postprint del document publicat a: http://dx.doi.org/10.1007/s00216-015-8899-4-
dc.relation.ispartofAnalytical and Bioanalytical Chemistry, 2015, vol. 407, num. 24, p. 7369-7378-
dc.relation.urihttp://dx.doi.org/10.1007/s00216-015-8899-4-
dc.rights(c) Springer Verlag, 2015-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationMedicaments veterinaris-
dc.subject.classificationEspectrometria de masses amb ionització per electroesprai-
dc.subject.otherVeterinary drugs-
dc.subject.otherElectrospray ionization mass spectrometry-
dc.titleDesorption electrospray ionization-high resolution mass spectrometry for the screening of veterinary drugs in cross contaminated feddstuffs-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec653334-
dc.date.updated2016-05-09T09:31:33Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid26168975-
Appears in Collections:Articles publicats en revistes (Enginyeria Química i Química Analítica)

Files in This Item:
File Description SizeFormat 
653334.pdf302.85 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.