Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/108570
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRúbies Prat, Antoni-
dc.contributor.authorCentrich, Francesc-
dc.contributor.authorGranados i Juan, Mercè-
dc.date.accessioned2017-03-17T14:30:49Z-
dc.date.available2017-06-20T22:01:23Z-
dc.date.issued2016-06-20-
dc.identifier.issn1618-2642-
dc.identifier.urihttp://hdl.handle.net/2445/108570-
dc.description.abstractWe developed a Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method for the high throughput determination of 10 non-steroidal anti-inflammatory drugs (NSAIDs) in milk samples using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) with a triple quadrupole (QqQ) instrument and an electrospray ionization (ESI) source. The new extraction procedure is highly efficient, and we obtained absolute recoveries in the range 78.1-97.1 % for the extraction and clean-up steps. Chromatographic separation is performed in the gradient mode with a biphenyl column and acidic mobile phases consisting of water and acetonitrile containing formic acid. The chromatographic run time was about 12 min, and NSAID peaks showed a good symmetry factor. For MS/MS detection, we used multiple reaction monitoring (MRM) mode, using ESI in both positive and negative modes. Our method has been validated in compliance with the European Commission Decision 657/2002/EC, and we obtained very satisfactory results in inter-laboratory testing. Furthermore, we explored the use of a hybrid high resolution mass spectrometer, combining a quadrupole and an Orbitrap mass analyzer, for high resolution (HR) MS/MS detection of NSAIDs. We achieved lower NSAID quantification limits with Q-Orbitrap high resolution mass spectrometry (HRMS/MS) detection than those achieved with the QqQ instrument; however, its main feature is its very high selectivity, which makes HRMS/MS particularly suitable for confirmatory analysis.-
dc.format.extent10 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherSpringer Verlag-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1007/s00216-016-9679-5-
dc.relation.ispartofAnalytical and Bioanalytical Chemistry, 2016, vol. 408, num. 21, p. 5769-5778-
dc.relation.urihttps://doi.org/10.1007/s00216-016-9679-5-
dc.rights(c) Springer Verlag, 2016-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationCromatografia de líquids-
dc.subject.classificationEspectrometria de masses-
dc.subject.classificationAntiinflamatoris no esteroïdals-
dc.subject.classificationLlet-
dc.subject.otherLiquid chromatography-
dc.subject.otherMass spectrometry-
dc.subject.otherNonsteroidal anti-inflammatory agents-
dc.subject.otherMilk-
dc.titleAnalysis of non-steroidal anti-inflammatory drugs in milk using QuEChERS and liquid chromatography coupled to mass spectrometry: triple quadrupole versus Q-Orbitrap mass analyzers-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec669932-
dc.date.updated2017-03-17T14:30:50Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid27325465-
Appears in Collections:Articles publicats en revistes (Enginyeria Química i Química Analítica)

Files in This Item:
File Description SizeFormat 
669932.pdf149.34 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.