Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/119396
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRodríguez-Pérez, Raquel-
dc.contributor.authorCortés Giràldez, Roldàn-
dc.contributor.authorGuamán Novillo, Ana Verónica-
dc.contributor.authorPardo Martínez, Antonio-
dc.contributor.authorTorralba, Yolanda-
dc.contributor.authorGómez, Federico Pablo-
dc.contributor.authorRoca, Josep-
dc.contributor.authorBarberà i Mir, Joan Albert-
dc.contributor.authorCascante i Serratosa, Marta-
dc.contributor.authorMarco Colás, Santiago-
dc.date.accessioned2018-01-30T09:22:38Z-
dc.date.available2019-01-02T06:10:27Z-
dc.date.issued2018-01-02-
dc.identifier.issn1752-7155-
dc.identifier.urihttp://hdl.handle.net/2445/119396-
dc.description.abstractBreath analysis holds the promise of a non-invasive technique for the diagnosis of diverse respiratory conditions including COPD and lung cancer. Breath contains small metabolites that may be putative biomarkers of these conditions. However, the discovery of reliable biomarkers is a considerable challenge in the presence of both clinical and instrumental confounding factors. Among the latter, instrumental time drifts are highly relevant, as since question the short and long-term validity of predictive models. In this work we present a methodology to counter instrumental drifts using information from interleaved blanks for a case study of GC-MS data from breath samples. The proposed method includes feature filtering, and additive, multiplicative and multivariate drift corrections, the latter being based on Component Correction. Biomarker discovery was based on Genetic Algorithms in a filter configuration using Fisher´s ratio computed in the Partial Least Squares - Discriminant Analysis subspace as a figure of merit. Using our protocol, we have been able to find nine peaks that provide a statistically significant Area under the ROC Curve (AUC) of 0.75 for COPD discrimination. The method developed has been successfully validated using blind samples in short-term temporal validation. However, in the attempt to use this model for patient screening six months later was not successful. This negative result highlights the importance of increasing validation rigour when reporting biomarker discovery results-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherInstitute of Physics (IOP)-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1088/1752-7163/aaa492-
dc.relation.ispartofJournal of Breath Research, 2018-
dc.relation.urihttps://doi.org/10.1088/1752-7163/aaa492-
dc.rights(c) Institute of Physics (IOP), 2018-
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)-
dc.subject.classificationMarcadors bioquímics-
dc.subject.classificationRespiració-
dc.subject.classificationQuimiometria-
dc.subject.otherBiochemical markers-
dc.subject.otherRespiration-
dc.subject.otherChemometrics-
dc.titleInstrumental drift removal in GC-MS data for breath analysis: the short-term and long term temporal validation of putative biomarkers for COPD-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec675379-
dc.date.updated2018-01-30T09:22:38Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid29292699-
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)
Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)

Files in This Item:
File Description SizeFormat 
675379.pdf1.44 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.