Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/119473
Title: Low power operation of thermally-modulated metal oxide semiconductor gas sensors
Author: Burgués, Javier
Marco Colás, Santiago
Keywords: Telèfons intel·ligents
Metall-òxid-semiconductors
Detectors de gasos
Smartphones
Metal oxide semiconductors
Gas detectors
Issue Date: 25-Jan-2018
Publisher: MDPI
Abstract: Mobile applications based on gas sensing present new opportunities for low-cost air quality monitoring, safety, and healthcare. Metal oxide semiconductor (MOX) gas sensors represent the most prominent technology for integration into portable devices, such as smartphones and wearables. Traditionally, MOX sensors have been continuously powered to increase the stability of the sensing layer. However, continuous power is not feasible in many battery-operated applications due to power consumption limitations or the intended intermittent device operation. This work benchmarks two low-power, duty-cycling, and on-demand modes against the continuous power one. The duty-cycling mode periodically turns the sensors on and off and represents a trade-off between power consumption and stability. On-demand operation achieves the lowest power consumption by powering the sensors only while taking a measurement. Twelve thermally modulated SB-500-12 (FIS Inc. Jacksonville, FL, USA) sensors were exposed to low concentrations of carbon monoxide (0-9 ppm) with environmental conditions, such as ambient humidity (15-75% relative humidity) and temperature (21-27 C), varying within the indicated ranges. Partial Least Squares (PLS) models were built using calibration data, and the prediction error in external validation samples was evaluated during the two weeks following calibration. We found that on-demand operation produced a deformation of the sensor conductance patterns, which led to an increase in the prediction error by almost a factor of 5 as compared to continuous operation (2.2 versus 0.45 ppm). Applying a 10% duty-cycling operation of 10-min periods reduced this prediction error to a factor of 2 (0.9 versus 0.45 ppm). The proposed duty-cycling powering scheme saved up to 90% energy as compared to the continuous operating mode. This low-power mode may be advantageous for applications that do not require continuous and periodic measurements, and which can tolerate slightly higher prediction errors.
Note: Reproducció del document publicat a: https://doi.org/10.3390/s18020339
It is part of: Sensors, 2018, vol. 18, num. 2, p. 339-354
URI: http://hdl.handle.net/2445/119473
Related resource: https://doi.org/10.3390/s18020339
ISSN: 1424-8220
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)

Files in This Item:
File Description SizeFormat 
675892.pdf3.23 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons