dc.description.abstract | The influence of the experimental conditions (glutathione concentration and incubation time and temperature) concerning the covalent immobilization of glutathione via carbodiimide coupling on the behavior of a glutathione modified screen-printed carbon electrode obtained by electrografting is evaluated. The optimized parameters fasten the modification process and improve the performance of the sensor as compared to the usual procedure. This suggests the convenience of a tailored preparation of metal sensors based on metal-binding biomolecules such as glutathione. | - |
dc.format.extent | 9 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | MDPI | - |
dc.relation.isformatof | Reproducció del document publicat a: https://doi.org/10.3390/chemosensors5020012 | - |
dc.relation.ispartof | Chemosensors, 2017, vol. 5, num. 12 | - |
dc.relation.uri | https://doi.org/10.3390/chemosensors5020012 | - |
dc.rights | cc-by (c) Pérez-Ràfols, Clara et al., 2017 | - |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/es | - |
dc.source | Articles publicats en revistes (Enginyeria Química i Química Analítica) | - |
dc.subject.classification | Glutatió | - |
dc.subject.classification | Metalls pesants | - |
dc.subject.classification | Voltametria | - |
dc.subject.other | Glutathione | - |
dc.subject.other | Heavy metals | - |
dc.subject.other | Voltammetry | - |
dc.title | A chemically-bound glutathione sensor bioinspired by the defense of organisms against heavy metal contamination: Optimization of the immobilization conditions | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | info:eu-repo/semantics/publishedVersion | - |
dc.identifier.idgrec | 671426 | - |
dc.date.updated | 2018-03-19T14:58:38Z | - |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
Appears in Collections: | Articles publicats en revistes (Enginyeria Química i Química Analítica) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
671426.pdf | 1.68 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License