Please use this identifier to cite or link to this item:
http://hdl.handle.net/2445/124213
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kirby, Miranda | - |
dc.contributor.author | Ohtani, Keishi | - |
dc.contributor.author | Nickens, Taylor | - |
dc.contributor.author | Lopez Lisbona, Rosa Maria | - |
dc.contributor.author | Lee, Anthony M. D. | - |
dc.contributor.author | Shaipanich, Tawimas | - |
dc.contributor.author | Lane, Pierre | - |
dc.contributor.author | Macaulay, Calum | - |
dc.contributor.author | Lam, Stephen | - |
dc.contributor.author | Coxson, Harvey O. | - |
dc.date.accessioned | 2018-09-03T11:34:18Z | - |
dc.date.available | 2018-09-03T11:34:18Z | - |
dc.date.issued | 2015-11-01 | - |
dc.identifier.uri | http://hdl.handle.net/2445/124213 | - |
dc.description.abstract | Optical coherence tomography (OCT) is a promising imaging technique to evaluate small airway remodeling. However, the short-term insertion-reinsertion reproducibility of OCT for evaluating the same bronchial pathway has yet to be established. We evaluated 74 OCT data sets from 38 current or former smokers twice within a single imaging session. Although the overall insertion-reinsertion airway wall thickness (WT) measurement coefficient of variation (CV) was moderate at 12%, much of the variability between repeat imaging was attributed to the observer; CV for repeated measurements of the same airway (intra-observer CV) was 9%. Therefore, reproducibility may be improved by introduction of automated analysis approaches suggesting that OCT has potential to be an in-vivo method for evaluating airway remodeling in future longitudinal and intervention studies. (C) 2015 Optical Society of America | - |
dc.format.extent | 13 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | OSA Publishing | - |
dc.relation.isformatof | Reproducció del document publicat a: http://dx.doi.org/10.1364/BOE.6.004365 | - |
dc.relation.ispartof | Biomedical Optics Express, 2015, vol. 6, num. 11, p. 4365-4377 | - |
dc.relation.uri | http://dx.doi.org/10.1364/BOE.6.004365 | - |
dc.rights | (c) Optical Society, 2015 | - |
dc.source | Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL)) | - |
dc.subject.classification | Òptica fisiològica | - |
dc.subject.classification | Biotecnologia | - |
dc.subject.other | Physiological optics | - |
dc.subject.other | Biotechnology | - |
dc.title | Reproducibility of optical coherence tomography airway imaging | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | info:eu-repo/semantics/publishedVersion | - |
dc.date.updated | 2018-07-25T07:56:49Z | - |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
dc.identifier.pmid | 26601002 | - |
Appears in Collections: | Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL)) |