Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/125608
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPérez Moreno, Álvaro-
dc.contributor.authorDominguez, Mara-
dc.contributor.authorMigliorelli, Federico-
dc.contributor.authorGratacós Solsona, Eduard-
dc.contributor.authorPalacio, Montse-
dc.contributor.authorBonet Carné, Elisenda-
dc.date.accessioned2018-10-24T16:54:32Z-
dc.date.available2019-03-30T06:10:25Z-
dc.date.issued2018-09-30-
dc.identifier.issn0278-4297-
dc.identifier.urihttp://hdl.handle.net/2445/125608-
dc.description.abstractOBJECTIVES: To compare the robustness of several methods based on quantitative ultrasound (US) texture analysis to evaluate its feasibility for extracting features from US images to use as a clinical diagnostic tool. METHODS: We compared, ranked, and validated the robustness of 5 texture-based methods for extracting textural features from US images acquired under different conditions. For comparison and ranking purposes, we used 13,171 non-US images from widely known available databases (OUTEX [University of Oulu, Oulu, Finland] and PHOTEX [Texture Lab, Heriot-Watt University, Edinburgh, Scotland]), which were specifically acquired under different controlled parameters (illumination, resolution, and rotation) from 103 textures. The robustness of those methods with better results from the non-US images was validated by using 666 fetal lung US images acquired from singleton pregnancies. In this study, 2 similarity measurements (correlation and Chebyshev distances) were used to evaluate the repeatability of the features extracted from the same tissue images. RESULTS: Three of the 5 methods (gray-level co-occurrence matrix, local binary patterns, and rotation-invariant local phase quantization) had favorably robust performance when using the non-US database. In fact, these methods showed similarity values close to 0 for the acquisition variations and delineations. Results from the US database confirmed robustness for all of the evaluated methods (gray-level co-occurrence matrix, local binary patterns, and rotation-invariant local phase quantization) when comparing the same texture obtained from different regions of the image (proximal/distal lungs and US machine brand stratification). CONCLUSIONS: Our results confirmed that texture analysis can be robust (high similarity for different condition acquisitions) with potential to be included as a clinical tool.-
dc.format.extent40 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherAmerican Institute of Ultrasound in Medicine-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1002/jum.14824-
dc.relation.ispartofJournal of Ultrasound in Medicine, 2018-
dc.relation.urihttps://doi.org/10.1002/jum.14824-
dc.rights(c) American Institute of Ultrasound in Medicine, 2018-
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)-
dc.subject.classificationEcografia fetal-
dc.subject.otherFetal ultrasonic imaging-
dc.titleClinical feasibility of quantitative ultrasound texture analysis: A robustness study using fetal lung ultrasound images-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec682662-
dc.date.updated2018-10-24T16:54:32Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid30269384-
Appears in Collections:Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
Articles publicats en revistes (BCNatal Fetal Medicine Research Center)

Files in This Item:
File Description SizeFormat 
682662.pdf594.18 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.