Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/127631
Full metadata record
DC FieldValueLanguage
dc.contributor.authorZaman, Zahur-
dc.contributor.authorBlanckaert, N.-
dc.contributor.authorCobbaert, Ch.-
dc.contributor.authorGillery, P.-
dc.contributor.authorHagemann, P.-
dc.contributor.authorLuthe, H.-
dc.contributor.authorMotta, R.-
dc.contributor.authorPatrono, D.-
dc.contributor.authorJionsué, M. A.-
dc.contributor.authorTorralba Rodríguez, Antonio-
dc.contributor.authorCastiñeiras, Jaime-
dc.contributor.authorFuentes i Arderiu, Xavier-
dc.contributor.authorBablok, Wolfgang-
dc.contributor.authorDomke, I.-
dc.contributor.authorStockmann, Wolfgang-
dc.date.accessioned2019-01-25T15:31:28Z-
dc.date.available2019-01-25T15:31:28Z-
dc.date.issued1993-12-
dc.identifier.issn0142-0453-
dc.identifier.urihttps://hdl.handle.net/2445/127631-
dc.description.abstractThe analytical performance and practicability of the Boehringer Mannheim (BM)/mtaci 91 analysis system have been assessed in a multicentre evaluation, which involved six laboratories from European countries. Analytes commonly used in classical clinical chemistry were tested in a core programme, which mainlyfollowed lhe ECCLS guidelines. In addition, a satellite programme covered other analytes, such as proteins, drugs and urine analytes. In total, the study comprised more than 100 000 data items collected over a three-month period. The evaluation was supported with 'Computer Aided Evaluation' (CAEv) and telecommunications. Acceptance criteria for the results were established at the beginning ofthe study. Nearly all ofthe analytes met the imprecision limits.' within-run imprecision (as CVs) was 2l/ofor enzyme and substrate assays, l%for ISE methods and 5l/o for immunoassays; between-day imprecision was 3l/ofor enzyme and substrate assays, 2o//o for ISE methods and 10% for immunoassays.-
dc.format.extent20 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherHindawi-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1155/S1463924693000264-
dc.relation.ispartofJournal of Automatic Chemistry, 1993, vol. 15, num. 6, p. 189-208-
dc.relation.urihttps://doi.org/10.1155/S1463924693000264-
dc.rightscc-by (c) Hindawi, 1993-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es-
dc.sourceArticles publicats en revistes (Ciències Fisiològiques)-
dc.subject.classificationQuímica analítica-
dc.subject.classificationProgrames d'ordinador-
dc.subject.otherAnalytical chemistry-
dc.subject.otherComputer programs-
dc.titleMulticentre evaluation of the Boehringer Mannheim / Hitachi 911 Analysis System-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec151339-
dc.date.updated2019-01-25T15:31:28Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid18924976-
Appears in Collections:Articles publicats en revistes (Ciències Fisiològiques)
Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
151339.pdf4.26 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons