dc.contributor.author | Barceló, Cristian | - |
dc.contributor.author | Serrano i Plana, Núria | - |
dc.contributor.author | Ariño Blasco, Cristina | - |
dc.contributor.author | Díaz Cruz, José Manuel | - |
dc.contributor.author | Esteban i Cortada, Miquel | - |
dc.date.accessioned | 2019-09-05T12:06:19Z | - |
dc.date.available | 2019-09-05T12:06:19Z | - |
dc.date.issued | 2015-10-28 | - |
dc.identifier.issn | 1040-0397 | - |
dc.identifier.uri | http://hdl.handle.net/2445/139347 | - |
dc.description.abstract | An Ex-situ antimony film screen-printed carbon electrode (Ex-situ SbSPCE) was successfully applied for the determination of Ni(II), by means of adsorptive stripping voltammetry using dimethylglyoxime as complexing agent, in a certified reference wastewater sample. This electrode is proposed as an alternative to more conventional antimony film electrodes. Ex-situ SbSPCE was analytically characterized and the obtained parameters suggest that Ex-situ SbSPCE behaves much better than both Ex-situ BiSPCE and BispSPE for Ni(II) determination. The results confirm the applicability of Ex-situ SbSPCE for the determination of low concentration levels of Ni(II) in natural samples with a very high reproducibility and good trueness. | - |
dc.format.extent | 5 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Wiley-VCH | - |
dc.relation.isformatof | Versió postprint del document publicat a: https://doi.org/10.1002/elan.201500511 | - |
dc.relation.ispartof | Electroanalysis, 2015, vol. 28, num. 3, p. 640-644 | - |
dc.relation.uri | https://doi.org/10.1002/elan.201500511 | - |
dc.rights | (c) Wiley-VCH, 2015 | - |
dc.source | Articles publicats en revistes (Enginyeria Química i Química Analítica) | - |
dc.subject.classification | Níquel | - |
dc.subject.classification | Voltametria | - |
dc.subject.classification | Anàlisi electroquímica | - |
dc.subject.other | Nickel | - |
dc.subject.other | Voltammetry | - |
dc.subject.other | Electrochemical analysis | - |
dc.title | Ex-situ antimony screen-printed carbon electrode for voltammetric determination of Ni(II) - ions in wastewater | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | info:eu-repo/semantics/acceptedVersion | - |
dc.identifier.idgrec | 654686 | - |
dc.date.updated | 2019-09-05T12:06:20Z | - |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
Appears in Collections: | Articles publicats en revistes (Enginyeria Química i Química Analítica) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
654686.pdf | 243.47 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.