Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/145218
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSepúlveda Martínez, Álvaro-
dc.contributor.authorGarcía-Otero, Laura-
dc.contributor.authorSoveral, Iris-
dc.contributor.authorGuirado, Laura-
dc.contributor.authorValenzuela Alcaraz, Brenda I.-
dc.contributor.authorTorres, Ximena-
dc.contributor.authorRodríguez López, Mérida-
dc.contributor.authorGratacós Solsona, Eduard-
dc.contributor.authorGómez, Olga-
dc.contributor.authorCrispi Brillas, Fàtima-
dc.date.accessioned2019-11-21T11:05:26Z-
dc.date.available2019-11-21T11:05:26Z-
dc.date.issued2018-02-11-
dc.identifier.issn1476-7058-
dc.identifier.urihttp://hdl.handle.net/2445/145218-
dc.description.abstractOBJECTIVE: M-mode and 2D have been proposed for evaluating fetal myocardial thickness. However, studies comparing the performance of both modalities are lacking. We aimed to compare 2D versus M-mode reproducibility for assessing myocardial wall thicknesses. METHODS: A prospective study including 45 healthy fetuses from low-risk pregnancies evaluated between 18 and 41 weeks of gestation. Left and right ventricular free-wall and septal myocardial thicknesses were measured at end-diastole (ED) and end-systole (ES) in transverse 4-chamber view using 2D and M-mode. Intra- and interobserver reproducibility was evaluated by the concordance correlation coefficient (CCC). Both techniques were compared by t-test of the CCC. RESULTS: 2D and M-mode demonstrated excellent and similar intraobserver repeatability, with the best concordance in ES septal thickness (M-mode CCC 0.956 versus 2D-mode CCC 0.914). Interobserver reproducibility demonstrated also a high concordance, optimal in ES left ventricular free wall (M-mode 0.925 versus 2 D 0.855). Comparison of both techniques demonstrated a high concordance in all measurements, except for ED septal thickness with better reproducibility using M-mode (CCC 0.954 versus 0.847, p = .017). CONCLUSIONS: 2D and M-mode can be used in a reproducible manner for measuring fetal myocardial thickness, with a slightly better performance of M-mode for assessing ED septal wall thickness.-
dc.format.extent24 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherInforma UK Ltd.-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1080/14767058.2018.1432041-
dc.relation.ispartofJournal Of Maternal-Fetal & Neonatal Medicine, 2018, vol. 32, num. 14, p. 2319-2327-
dc.relation.urihttps://doi.org/10.1080/14767058.2018.1432041-
dc.rights(c) Informa UK Ltd., 2018-
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)-
dc.subject.classificationEcocardiografia-
dc.subject.classificationCor-
dc.subject.classificationFetus-
dc.subject.classificationEstudi de casos-
dc.subject.otherEchocardiography-
dc.subject.otherHeart-
dc.subject.otherFetus-
dc.subject.otherCase studies-
dc.titleComparison of 2D versus M-mode echocardiography for assessing fetal myocardial wall thickness-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec678938-
dc.date.updated2019-11-21T11:05:26Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
Articles publicats en revistes (BCNatal Fetal Medicine Research Center)

Files in This Item:
File Description SizeFormat 
678938.pdf717.62 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.