Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/155378
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHeckel, B.-
dc.contributor.authorRodríguez Fernández, Diana-
dc.contributor.authorTorrentó Aguerri, Clara-
dc.contributor.authorMeyer, A.-
dc.contributor.authorPalau, Jordi-
dc.contributor.authorDomènech Ortí, Cristina-
dc.contributor.authorRosell, Mònica-
dc.contributor.authorSoler i Gil, Albert-
dc.contributor.authorHunkeler, D.-
dc.contributor.authorElsner, M.-
dc.date.accessioned2020-04-15T16:19:47Z-
dc.date.available2020-04-15T16:19:47Z-
dc.date.issued2017-02-10-
dc.identifier.issn0003-2700-
dc.identifier.urihttp://hdl.handle.net/2445/155378-
dc.description.abstractCompound-specific chlorine isotope analysis of tetrachloromethane (CCl4) and trichloromethane (CHCl3) was explored by both, gas chromatography-isotope ratio mass spectrometry (GC-IRMS) and GC-quadrupole MS (GC-qMS), where GC-qMS was validated in an interlaboratory comparison between Munich and Neuchâtel with the same type of commercial GC-qMS instrument. GC-IRMS measurements analyzed CCl isotopologue ions, whereas GC-qMS analyzed the isotopologue ions CCl3, CCl2, CCl (of CCl4) and CHCl3, CHCl2, CHCl (of CHCl3), respectively. Lowest amount dependence (good linearity) was obtained (i) in H-containing fragment ions where interference of 35Cl- to 37Cl-containing ions was avoided; (ii) with tuning parameters favoring one predominant rather than multiple fragment ions in the mass spectra. Optimized GC-qMS parameters (dwell time 70 ms, 2 most abundant ions) resulted in standard deviations of 0.2 (CHCl3) and 0.4 (CCl4), which are only about twice as large as 0.1 and 0.2 for GC-IRMS. To compare also the trueness of both methods and laboratories, samples from CCl4 and CHCl3 degradation experiments were analyzed and calibrated against isotopically different reference standards for both CCl4 and CHCl3 (two of each). Excellent agreement confirms that true results can be obtained by both methods provided that a consistent set of isotopically characterized reference materials is used.-
dc.format.extent12 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherAmerican Chemical Society-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1021/acs.analchem.6b04129-
dc.relation.ispartofAnalytical Chemistry, 2017, vol. 89, num. 6, p. 3411-3420-
dc.relation.urihttps://doi.org/10.1021/acs.analchem.6b04129-
dc.rights(c) American Chemical Society , 2017-
dc.sourceArticles publicats en revistes (Mineralogia, Petrologia i Geologia Aplicada)-
dc.subject.classificationGeoquímica-
dc.subject.classificationDegradació dels sòls-
dc.subject.otherGeochemistry-
dc.subject.otherSoil degradation-
dc.titleCompound-Specific Chlorine Isotope Analysis of Tetrachloromethane and Trichloromethane by Gas Chromatography-Isotope Ratio Mass Spectrometry vs Gas Chromatography-Quadrupole Mass Spectrometry: Method Development and Evaluation of Precision and Trueness-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec664830-
dc.date.updated2020-04-15T16:19:47Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Mineralogia, Petrologia i Geologia Aplicada)

Files in This Item:
File Description SizeFormat 
664830.pdf597.72 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.