Please use this identifier to cite or link to this item:
https://hdl.handle.net/2445/171983
Title: | High-throughput wide dynamic range procedure for the simultaneous quantification of nicotine and cotinine in multiple biological matrices using hydrophilic interaction liquid chromatography-tandem mass spectrometry |
Author: | Pérez Ortuño, Raúl Martínez Sánchez, José M. Fernández Muñoz, Esteve Pascual, José Antonio |
Keywords: | Espectrometria de masses Nicotina Marcadors bioquímics Mass spectrometry Nicotine Biochemical markers |
Issue Date: | 5-Sep-2015 |
Publisher: | Springer Verlag |
Abstract: | A straightforward, high-throughput method was developed and fully validated for the simultaneous determination of the specific tobacco biomarkers nicotine and its main metabolite cotinine in a wide dynamic range and supporting the most common human biological matrices (urine, oral fluid and hair). Sample preparation was performed inside the very HPLC injection vials by pipetting 0.5 mL of the liquid samples, deuterated internal standards in alkaline solution and dichloromethane as extraction solvent. Solid samples (i.e. around 10 mg hair) were first submitted to alkaline digestion in the HPLC vials and processed accordingly. The organic phase (reached through the upper aqueous layer) was directly injected without further treatment. Instrumental analysis was performed using hydrophilic interaction (HILIC) ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Total chromatographic time was 2 min. The method covers a wide dynamic range making it fit-for-purpose for the analysis of samples covering entire populations, irrespective of the level of exposure or tobacco use. Calibration curves (r 2 > 0.995) covered the range 1-2000 ng/mL (or 0.05-100 ng/mg hair) for nicotine and 0.1-2000 ng/mL (or 0.005-100 ng/mg hair) for cotinine. Within-run and between-run precision and accuracy were typically below 10 %, and always below 20 % at the lower limit of quantification. The method was successfully applied to the analysis of samples from different projects involving multiple matrices. |
Note: | Versió postprint del document publicat a: https://doi.org/10.1007/s00216-015-8993-7 |
It is part of: | Analytical and Bioanalytical Chemistry, 2015, vol. 407, p. 8463-8473 |
URI: | https://hdl.handle.net/2445/171983 |
Related resource: | https://doi.org/10.1007/s00216-015-8993-7 |
ISSN: | 1618-2642 |
Appears in Collections: | Articles publicats en revistes (Ciències Clíniques) Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL)) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
656863.pdf | 482.45 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.