Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/173393
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUsmani Kashif-
dc.contributor.authorO'Connor, Timothy-
dc.contributor.authorShen, Xin-
dc.contributor.authorMarasco, Pete-
dc.contributor.authorCarnicer González, Arturo-
dc.contributor.authorDey, Dipak-
dc.contributor.authorJavidi, Bahram-
dc.date.accessioned2021-01-25T10:42:34Z-
dc.date.available2021-01-25T10:42:34Z-
dc.date.issued2020-06-15-
dc.identifier.issn1094-4087-
dc.identifier.urihttp://hdl.handle.net/2445/173393-
dc.description.abstractThree-dimensional (3D) polarimetric integral imaging (InIm) to extract the 3D polarimetric information of objects in photon-starved conditions is investigated using a low noise visible range camera and a long wave infrared (LWIR) range camera, and the performance between the two sensors is compared. Stokes polarization parameters and degree of polarization (DoP) are calculated to extract the polarimetric information of the 3D scene while integral imaging reconstruction provides depth information and improves the performance of low-light imaging tasks. An LWIR wire grid polarizer and a linear polarizer film are used as polarimetric objects for the LWIR range and visible range cameras, respectively. To account for a limited number of photons per pixel using the visible range camera in low light conditions, we apply a mathematical restoration model at each elemental image of visible camera to enhance the signal. We show that the low noise visible range camera may outperform the LWIR camera in detection of polarimetric objects under low illumination conditions. Our experiments indicate that for 3D polarimetric measurements under photon-starved conditions, visible range sensing may produce a signal-to-noise ratio (SNR) that is not lower than the LWIR range sensing. We derive the probability density function (PDF) of the 2D and 3D degree of polarization (DoP) images and show that the theoretical model demonstrates agreement to that of the experimentally obtained results. To the best of our knowledge, this is the first report comparing the polarimetric imaging performance between visible range and infrared (IR) range sensors under photon-starved conditions and the relevant statistical models of 3D polarimetric integral imaging.-
dc.format.extent14 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherOptical Society of America-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1364/OE.395301-
dc.relation.ispartofOptics Express, 2020, vol. 28, num. 13, p. 19281-19294-
dc.relation.urihttps://doi.org/10.1364/OE.395301-
dc.rights(c) Optical Society of America, 2020-
dc.sourceArticles publicats en revistes (Física Aplicada)-
dc.subject.classificationVisualització tridimensional-
dc.subject.classificationPolarització (Llum)-
dc.subject.classificationFotografia infraroja-
dc.subject.otherThree-dimensional display systems-
dc.subject.otherPolarization (Light)-
dc.subject.otherInfrared photography-
dc.titleThree-dimensional polarimetric integral imaging in photon-starved conditions: performance comparison between visible and long wave infrared imaging-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec706247-
dc.date.updated2021-01-25T10:42:35Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Física Aplicada)

Files in This Item:
File Description SizeFormat 
706247.pdf4.06 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.