Please use this identifier to cite or link to this item:
https://hdl.handle.net/2445/176192
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Torres Rivero, Karina | - |
dc.contributor.author | Pérez Ràfols, Clara | - |
dc.contributor.author | Bastos Arrieta, Julio | - |
dc.contributor.author | Florido, Antonio | - |
dc.contributor.author | Martí, Vicenç | - |
dc.contributor.author | Serrano i Plana, Núria | - |
dc.date.accessioned | 2021-04-12T13:07:49Z | - |
dc.date.available | 2021-04-12T13:07:49Z | - |
dc.date.issued | 2020-06-30 | - |
dc.identifier.issn | 2079-4991 | - |
dc.identifier.uri | https://hdl.handle.net/2445/176192 | - |
dc.description.abstract | Carbon-nanofiber-based screen-printed electrodes modified with silver nanoparticles (Ag-NP-SPCNFEs) were tested in a pioneering manner for the direct determination of As(V) at low μg L-1 levels by means of differential pulse anodic stripping voltammetry. Screen-printed electrodes were modified with two different types of Ag-NPs, nanoseeds (NS), and nanoprisms (NPr) and characterized both microscopically and electrochemically. Furthermore, after optimizing the direct voltammetric determination of As(V), the analytical performance of considered sensors was compared for the direct determination of As(V). These results suggest that Ag-NS offer a better analytical response compared to Ag-NPr, with a detection and quantification limit of 0.6 and 1.9 µg L-1, respectively. The proposed methodology was validated using a spiked tap water sample with a very high reproducibility and good agreement with inductively coupled plasma - mass spectrometry (ICP-MS) measurements. | - |
dc.format.extent | 10 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | MDPI | - |
dc.relation.isformatof | Reproducció del document publicat a: https://doi.org/10.3390/nano10071280 | - |
dc.relation.ispartof | Nanomaterials, 2020, vol. 10, num. 7, p. 1280 | - |
dc.relation.uri | https://doi.org/10.3390/nano10071280 | - |
dc.rights | cc-by (c) Torres Rivero, Karina et al., 2020 | - |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/es | - |
dc.source | Articles publicats en revistes (Enginyeria Química i Química Analítica) | - |
dc.subject.classification | Elèctrodes de carboni | - |
dc.subject.classification | Microscòpia | - |
dc.subject.other | Carbon electrodes | - |
dc.subject.other | Microscopy | - |
dc.title | Direct As(V) Determination Using Screen-Printed Electrodes Modified with Silver Nanoparticles | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | info:eu-repo/semantics/publishedVersion | - |
dc.identifier.idgrec | 706879 | - |
dc.date.updated | 2021-04-12T13:07:49Z | - |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
dc.identifier.pmid | 32629854 | - |
Appears in Collections: | Articles publicats en revistes (Enginyeria Química i Química Analítica) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
706879.pdf | 1.7 MB | Adobe PDF | View/Open |
This item is licensed under a
Creative Commons License