Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/180561
Title: Cardiorespiratory coordination during exercise in adults with Down syndrome
Author: Oviedo, Guillermo R.
Garcia Retortillo, Sergi
Carbó-Carreté, Maria
Guerra Balic, Miriam
Balagué Serre, Natàlia
Javierre Garcés, Casimiro F.
Guàrdia-Olmos, Joan, 1958-
Keywords: Síndrome de Down
Pressió sanguínia
Fisiologia de l'exercici
Down syndrome
Blood pressure
Exercise physiology
Issue Date: 8-Sep-2021
Publisher: Frontiers Media
Abstract: Introduction: Down syndrome (DS) is a chromosomal disorder affecting simultaneously cardiovascular and respiratory systems. There is no research studying the coupling between these systems during cardiorespiratory exercise testing in a population with DS. Cardiorespiratory coordination (CRC), evaluated through principal component analysis (PCA), measures the covariation of cardiorespiratory variables during exercise. Objective: to investigate and compare CRC in adults with and without DS during maximal cardiorespiratory exercise testing. Methods: fifteen adults with DS and 15 adults without disabilities performed a maximal cardiorespiratory exercise test on a treadmill. First, the slope, and afterward the velocity was increased regularly until participants reached exhaustion. The time series of six selected cardiorespiratory variables [ventilation per minute, an expired fraction of O2, the expired fraction of CO2, heart rate, systolic blood pressure (SBP), and diastolic blood pressure (DBP)] were extracted for the analysis. The number of principal components (PCs), the first PC eigenvalues (PC1), and the information entropy were computed for each group (non-DS and DS) and compared using a t-test or a Mann-Whitney U test. Results: two PCs in the non-DS group and three PCs in the DS group captured the variance of the studied cardiorespiratory variables. The formation of an additional PC in the DS group was the result of the shift of SBP and DBP fromthe PC1 cluster of variables. Eigenvalues of PC1 were higher in the non-DS (U = 30; p = 0.02; d = 1.47) than in the DS group, and the entropy measure was higher in the DS compared with the non-DS group (U = 37.5; p = 0.008; d = 0.70). Conclusion: adults with Down syndrome showed higher CRC dimensionality and a higher entropy measure than participants without disabilities. Both findings point toward a lower efficiency of the cardiorespiratory function during exercise in participants with DS. CRC appears as an alternative measure to investigate the cardiorespiratory function and its response to exercise in the DS population.
Note: Reproducció del document publicat a: https://doi.org/10.3389/fphys.2021.704062
It is part of: Frontiers in Physiology, 2021, vol. 12, p. 704062
URI: http://hdl.handle.net/2445/180561
Related resource: https://doi.org/10.3389/fphys.2021.704062
ISSN: 1664-042X
Appears in Collections:Articles publicats en revistes (Ciències Fisiològiques)

Files in This Item:
File Description SizeFormat 
714486.pdf940.91 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons