El CRAI romandrà tancat del 24 de desembre de 2025 al 6 de gener de 2026. La validació de documents es reprendrà a partir del 7 de gener de 2026.
El CRAI permanecerá cerrado del 24 de diciembre de 2025 al 6 de enero de 2026. La validación de documentos se reanudará a partir del 7 de enero de 2026.
From 2025-12-24 to 2026-01-06, the CRAI remain closed and the documents will be validated from 2026-01-07.
 
Carregant...
Miniatura

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc by (c) Calvo Maroto, Ana M. et al, 2021
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/183117

Comparative Study of Refraction between Wave Front-Based Refraction and Autorefraction without and with Cycloplegia in Children and Adolescents

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

The main aim of this study was to compare refraction measurements with and without cycloplegia from two refractors devices, (TRK-2P autorefractometer (TRK-2P) and wavefront-based refraction Visionix 130 (VX130)) in children and adolescents. This descriptive observational study included 20 myopic eyes and 40 hyperopic eyes measured in two different Spanish hospitals. Cycloplegia was carried out by three drops of cyclopentolate hydrochloride 1% (Colircusi cycloplegic, Alcon Healthcare S.A., Barcelona). The mean age of the myopia group was 12.40 +/- 3.48 years; for the hyperopia group, the mean age was 7.37 +/- 2.47 years. In the myopia group, autorefraction and wavefront-based refraction did not show clinically significant differences in any components between with and without cycloplegia. The hyperopia group showed statistical and clinically significant differences in sphere and SE components between relaxed and non-relaxed states of accommodation, although the cylindrical components were not clinically different. In this study, we considered a value of >= 0.50D as a clinically significant difference in refraction. Therefore, both devices were capable of obtaining accurate refractions without cyclopegia in myopia children, although they did not avoid instrument myopia and accommodation involved in hyperopia children. Moreover, both refractometers could be useful for astigmatism monitoring in children without the need for cycloplegic drops.

Matèries (anglès)

Citació

Citació

CALVO MAROTO, Ana m., LLORENTE GONZÁLEZ, Sara, BEZUNARTEA BEZUNARTEA, Jaione, HURTADO CEÑA, Francisco javier, BERROZPE VILLABONA, Clara, BILBAO MALAVÉ, Valentina, PIÑERO, David p., BARRIO BARRIO, Jesús, RECALDE MAESTRE, Sergio. Comparative Study of Refraction between Wave Front-Based Refraction and Autorefraction without and with Cycloplegia in Children and Adolescents. _Children_. 2022. Vol.  vol 9, núm. num 1. [consulta: 2 de gener de 2026]. ISSN: 2227-9067. [Disponible a: https://hdl.handle.net/2445/183117]

Exportar metadades

JSON - METS

Compartir registre