Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/183966
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLi, Hongqiang-
dc.contributor.authorAn, Zhixuan-
dc.contributor.authorZuo, Shasha-
dc.contributor.authorZhu, Wei-
dc.contributor.authorZhang, Zhen-
dc.contributor.authorZhang, Shanshan-
dc.contributor.authorZhang, Cheng-
dc.contributor.authorSong, Wenchao-
dc.contributor.authorMao, Quanhua-
dc.contributor.authorMu, Yuxin-
dc.contributor.authorLi, Enbang-
dc.contributor.authorPrades García, Juan Daniel-
dc.date.accessioned2022-03-09T18:11:16Z-
dc.date.available2022-03-09T18:11:16Z-
dc.date.issued2021-09-01-
dc.identifier.issn1424-8220-
dc.identifier.urihttp://hdl.handle.net/2445/183966-
dc.description.abstractHeart disease is the leading cause of death for men and women globally. The residual network (ResNet) evolution of electrocardiogram (ECG) technology has contributed to our understanding of cardiac physiology. We propose an artificial intelligence-enabled ECG algorithm based on an improved ResNet for a wearable ECG. The system hardware consists of a wearable ECG with conductive fabric electrodes, a wireless ECG acquisition module, a mobile terminal App, and a cloud diagnostic platform. The algorithm adopted in this study is based on an improved ResNet for the rapid classification of different types of arrhythmia. First, we visualize ECG data and convert one-dimensional ECG signals into two-dimensional images using Gramian angular fields. Then, we improve the ResNet-50 network model, add multistage shortcut branches to the network, and optimize the residual block. The ReLu activation function is replaced by a scaled exponential linear units (SELUs) activation function to improve the expression ability of the model. Finally, the images are input into the improved ResNet network for classification. The average recognition rate of this classification algorithm against seven types of arrhythmia signals (atrial fibrillation, atrial premature beat, ventricular premature beat, normal beat, ventricular tachycardia, atrial tachycardia, and sinus bradycardia) is 98.3%.-
dc.format.extent19 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherMDPI-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/s21186043-
dc.relation.ispartofSensors, 2021, vol. 21, num. 18, p. 6043-6061-
dc.relation.urihttps://doi.org/10.3390/s21186043-
dc.rightscc-by (c) Li, Hongqiang et al., 2021-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)-
dc.subject.classificationComputació en núvol-
dc.subject.classificationIntel·ligència artificial-
dc.subject.classificationElectrocardiografia-
dc.subject.otherCloud computing-
dc.subject.otherArtificial intelligence-
dc.subject.otherElectrocardiography-
dc.titleArtificial Intelligence-Enabled ECG Algorithm Based on Improved Residual Network for Wearable ECG-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec717072-
dc.date.updated2022-03-09T18:11:16Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)

Files in This Item:
File Description SizeFormat 
717072.pdf6.94 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons