Title: Noninvasive assessment of neuromechanical coupling and mechanical efficiency of parasternal intercostal muscle during inspiratory threshold loading
Author: Lozano García, Manuel
Estrada Petrocelli, Luis
Torres, Abel
Rafferty, Gerrard F.
Moxham, John
Jolley, Caroline J.
Jane, Raimon
Keywords: Músculs respiratoris
Electromiografia
Diafragma (Anatomia)
Respiratory muscles
Electromyography
Diaphragm
Issue Date: 1-Mar-2021
Publisher: MDPI
Abstract: This study aims to investigate noninvasive indices of neuromechanical coupling (NMC) and mechanical efficiency (MEff) of parasternal intercostal muscles. Gold standard assessment of diaphragm NMC requires using invasive techniques, limiting the utility of this procedure. Nonin-vasive NMC indices of parasternal intercostal muscles can be calculated using surface mechano-myography (sMMGpara) and electromyography (sEMGpara). However, the use of sMMGpara as an in-spiratory muscle mechanical output measure, and the relationships between sMMGpara, sEMGpara, and simultaneous invasive and noninvasive pressure measurements have not previously been eval-uated. sEMGpara, sMMGpara, and both invasive and noninvasive measurements of pressures were recorded in twelve healthy subjects during an inspiratory loading protocol. The ratios of sMMGpara to sEMGpara, which provided muscle-specific noninvasive NMC indices of parasternal intercostal muscles, showed nonsignificant changes with increasing load, since the relationships between sMMGpara and sEMGpara were linear (R2 = 0.85 (0.75–0.9)). The ratios of mouth pressure (Pmo) to sEMGpara and sMMGpara were also proposed as noninvasive indices of parasternal intercostal muscle NMC and MEff, respectively. These indices, similar to the analogous indices calculated using invasive transdiaphragmatic and esophageal pressures, showed nonsignificant changes during threshold loading, since the relationships between Pmo and both sEMGpara (R2 = 0.84 (0.77–0.93)) and sMMGpara (R2 = 0.89 (0.85–0.91)) were linear. The proposed noninvasive NMC and MEff indices of parasternal intercostal muscles may be of potential clinical value, particularly for the regular assessment of patients with disordered respiratory mechanics using noninvasive wearable and wireless devices.
Note: Reproducció del document publicat a: https://doi.org/10.3390/s21051781
It is part of: Sensors, 2021, vol. 21, num. 5, p. 1781
URI: http://hdl.handle.net/2445/186186
Related resource: https://doi.org/10.3390/s21051781
ISSN: 1424-8220
Appears in Collections:Articles publicats en revistes (Institut de Bioenginyeria de Catalunya (IBEC))

Files in This Item:
File Description SizeFormat 
2021_Sensors_Noninvasive_Jane.pdf1.35 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons