Please use this identifier to cite or link to this item:
http://hdl.handle.net/2445/188549
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Solórzano, Ana | - |
dc.contributor.author | Fonollosa Magrinyà, Jordi | - |
dc.contributor.author | Marco Colás, Santiago | - |
dc.date.accessioned | 2022-09-01T09:43:33Z | - |
dc.date.available | 2022-09-01T09:43:33Z | - |
dc.date.issued | 2017-08-09 | - |
dc.identifier.issn | 2504-3900 | - |
dc.identifier.uri | http://hdl.handle.net/2445/188549 | - |
dc.description.abstract | Chemical sensing may be better suited than conventional smoke-based detectors for the detection of certain type of fires, in particular in fires where smoke appears after gas emissions. However, chemical-based systems also respond to non-fire scenarios that also release volatiles. For this reason, discrimination models need to be trained under different fire and non-fire scenarios. This is usually performed in standard fire rooms, the access to which is very costly. In this work, we present a calibration model combining experiments from standard fire room and small-scale setup. Results show that the use of small-scale setup experiments improve the performance of the system. | - |
dc.format.extent | 4 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | MDPI | - |
dc.relation.isformatof | Reproducció del document publicat a: https://doi.org/10.3390/proceedings1040453 | - |
dc.relation.ispartof | MDPI Proceedings, 2017, vol. 1, num. 4, p. 453 | - |
dc.relation.uri | https://doi.org/10.3390/proceedings1040453 | - |
dc.rights | cc-by (c) Solórzano, Ana et al., 2017 | - |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | - |
dc.source | Comunicacions a congressos (Enginyeria Electrònica i Biomèdica) | - |
dc.subject.classification | Prevenció d'incendis | - |
dc.subject.classification | Detectors de gasos | - |
dc.subject.classification | Detectors químics | - |
dc.subject.classification | Olfacte | - |
dc.subject.other | Fire prevention | - |
dc.subject.other | Gas detectors | - |
dc.subject.other | Chemical detectors | - |
dc.subject.other | Smell | - |
dc.title | Improving Calibration of Chemical Gas Sensors for Fire Detection Using Small Scale Setups | - |
dc.type | info:eu-repo/semantics/other | - |
dc.type | info:eu-repo/semantics/publishedVersion | - |
dc.identifier.idgrec | 717795 | - |
dc.date.updated | 2022-09-01T09:43:34Z | - |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
Appears in Collections: | Comunicacions a congressos (Institut de Bioenginyeria de Catalunya (IBEC)) Comunicacions a congressos (Enginyeria Electrònica i Biomèdica) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
717795.pdf | 487.06 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License