Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/189554
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUstabasi, Gul S.-
dc.contributor.authorPérez Ràfols, Clara-
dc.contributor.authorSerrano i Plana, Núria-
dc.contributor.authorDíaz Cruz, José Manuel-
dc.date.accessioned2022-10-03T13:53:52Z-
dc.date.available2022-10-03T13:53:52Z-
dc.date.issued2022-08-01-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://hdl.handle.net/2445/189554-
dc.description.abstractThe simultaneous voltammetric determination of iron and copper was accomplished by an unmodified screen-printed carbon electrode based on the complexation with o-phenanthroline assisted by the reducing agent ferrocyanide. The detection limits were 3.74 and 0.34 µg L−1 for iron and copper, respectively, and a linear response was observed from 12.5 to 400 µg L−1 for iron and from 1.14 to 400 µg L−1 for copper. This method successfully avoids interferences between iron and copper while allowing the simultaneous determination of both low and high metal concentrations usually found in the environment. Finally, a certified wastewater reference material was successfully analyzed, confirming the precision and accuracy of the proposed method.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.microc.2022.107597-
dc.relation.ispartofMicrochemical Journal, 2022, vol. 179, p. 107597-
dc.relation.urihttps://doi.org/10.1016/j.microc.2022.107597-
dc.rightscc-by-nc-nd (c) Ustabasi, Gul S. et al., 2022-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationVoltametria-
dc.subject.classificationFerro-
dc.subject.classificationMedi ambient-
dc.subject.otherVoltammetry-
dc.subject.otherIron-
dc.subject.otherNatural environment-
dc.titleSimultaneous determination of iron and copper using screen-printed carbon electrodes by adsorptive stripping voltammetry with o-phenanthroline.-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec723483-
dc.date.updated2022-10-03T13:53:52Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Institut de Recerca de l'Aigua (IdRA))
Articles publicats en revistes (Enginyeria Química i Química Analítica)

Files in This Item:
File Description SizeFormat 
723483.pdf1.52 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons