Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/200887
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVargas, Ronny-
dc.contributor.authorRomero, Miquel-
dc.contributor.authorBerasategui, Tomás-
dc.contributor.authorNarváez Narváez, David A.-
dc.contributor.authorRamirez, Patricia-
dc.contributor.authorNardi Ricart, Anna-
dc.contributor.authorGarcía Montoya, Encarna-
dc.contributor.authorPérez Lozano, Pilar-
dc.contributor.authorSuñé i Negre, Josep M. (Josep Maria)-
dc.contributor.authorMoreno Castro, Cristina-
dc.contributor.authorHernández Munain, Cristina-
dc.contributor.authorSuñe, Carlos-
dc.contributor.authorSuñé Pou, Marc-
dc.date.accessioned2023-07-19T11:21:35Z-
dc.date.available2023-07-19T11:21:35Z-
dc.date.issued2023-05-01-
dc.identifier.issn2215-0382-
dc.identifier.urihttp://hdl.handle.net/2445/200887-
dc.description.abstractManufacturing lipid nanoparticles through microfluidic mixing can be approached from a Quality by Design perspective. Research involving critical process parameters seems to focus on the total flow and flow rate ratio, thus other process variables, such as dialysis, are underestimated. This study used a Design of Experiments to identify the influence of critical process parameters on particle size, polydispersity index, and zeta potential. A response surface Design of Experiments modeled the influence of: total flow (400 to 4000 mu L min-1); flow rate ratio (3 to 9) and dialysis (yes/no). Results suggest that dialysis is a crucial parameter that strongly influences particle size and zeta potential and moderately affects polydispersity index. The flow rate ratio's relevance decreases when dialysis is performed. As the purification method can change the influence of other process parameters, it should be an integrated part of the microfluidic manufacturing of lipid nanoparticles instead of an extra step.-
dc.format.extent9 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier BV-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.colcom.2023.100709-
dc.relation.ispartofColloid and Interface Science Communications, 2023, vol. 54, p. 100709-
dc.relation.urihttps://doi.org/10.1016/j.colcom.2023.100709-
dc.rightscc by-nc-nd (c) Vargas, Ronny et al., 2023-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.sourceArticles publicats en revistes (Farmàcia, Tecnologia Farmacèutica i Fisicoquímica)-
dc.subject.classificationDisseny d'experiments-
dc.subject.classificationNanopartícules-
dc.subject.classificationTecnologia farmacèutica-
dc.subject.otherExperimental design-
dc.subject.otherNanoparticles-
dc.subject.otherPharmaceutical technology-
dc.titleDialysis is a key factor modulating interactions between critical process parameters during the microfluidic preparation of lipid nanoparticles-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.date.updated2023-06-21T10:50:30Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Farmàcia, Tecnologia Farmacèutica i Fisicoquímica)
Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
1-s2.0-S221503822300016X-main.pdf4.21 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons