Title: Blood component requirements in liver transplantation: effect of 2 thromboelastometry-guided strategies for bolus fibrinogen infusion, the TROMBOFIB randomized trial
Author: Caballero Milán, Marta
Sabaté Pes, Antoni
Gutierrez, Rosa
Beltran, Joan
Pérez, Lourdes
Pujol, Roger
Viguera Fernández, Laura
Costa, Marta
Reyes, Raquel
Martinez, Alberto
Ojinaga, Gorka
Leon, Ariadna
Navarro Alcaraz, Antonio
Barquero, Marta
Alonso, Guillermo
Puig, Guillermo
Blasi, Annabel
Keywords: Fibrinogen
Transfusió de sang
Hemostàsia
Trasplantament hepàtic
Fibrinogen
Blood transfusion
Hemostasis
Hepatic transplantation
Issue Date: 10-Jan-2023
Publisher: Wiley
Abstract: Background: A low plasma fibrinogen level influences blood component transfusion. Thromboelastometry provides clinical guidance for fibrinogen replacement in liver transplantation (LT). Objectives: We hypothesized that infusions of fibrinogen concentrate to reach an A10FIBTEM value of 11 mm during LT could reduce red blood cell (RBC) and other component and fluid requirements in comparison to standard care. Methods: This randomized, blinded, multicenter trial in 3 hospitals enrolled 189 LTscheduled patients allocated to an intervention target (A10FIBTEM, 11 mm) or a standard target (A10FIBTEM, 8 mm); 176 patients underwent LT with fibrinogen replacement. Data were analyzed by intention-to-treat (intervention group, 91; control group, 85). Blood was extracted, and fibrinogen kits were prepared to bring each patient's fibrinogen level to the assigned target at the start of LT, after portal vein clamping, and after graft reperfusion. The main outcome was the proportion of patients requiring RBC transfusion during LT or within 24 hours. Results: The proportion of patients requiring RBCs did not differ between the groups: intervention, 74.7% (95% CI, 65.5%-83.3%); control, 72.9% (95% CI, 62.2%-82.0%); absolute difference, 1.8% (95% CI, −11.1% to 14.78%) (P = .922). Thrombotic events occurred in 4% of the patients in both groups; reoperation and retransplantation rates and mortality did not differ. Nearly 70% of the patients in both groups required fibrinogen concentrate to reach the target. Using an 11-mm A10FIBTEM target increased the maximum clot firmness without affecting safety. However, this change provided no clinical benefits. Conclusion: The similar low plasma fibrinogen concentrations could explain the lack of significant between-group outcomes.
Note: Reproducció del document publicat a: https://doi.org/10.1016/j.jtha.2022.10.025
It is part of: Journal Of Thrombosis And Haemostasis, 2023, vol. 21, p. 37-46
URI: http://hdl.handle.net/2445/201302
Related resource: https://doi.org/10.1016/j.jtha.2022.10.025
ISSN: 1538-7933
Appears in Collections:Articles publicats en revistes (Ciències Clíniques)
Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
727845.pdf646.31 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons