Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/202113
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRedón, Lídia-
dc.contributor.authorBeiranvand, Mahmoud Safar-
dc.contributor.authorSubirats i Vila, Xavier-
dc.contributor.authorRosés Pascual, Martí-
dc.date.accessioned2023-09-20T15:04:14Z-
dc.date.available2023-09-20T15:04:14Z-
dc.date.issued2023-10-09-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://hdl.handle.net/2445/202113-
dc.description.abstractThe Abraham's solvation parameter model, based on linear solvation energy relationships (LSER), allows the accurate characterization of the selectivity of chromatographic systems according to solute-solvent interactions (polarizability, dipolarity, hydrogen bonding, and cavity formation). However, this method, based on multilinear regression analysis, requires the measurement of the retention factors of a considerably high number of compounds, turning it into a time-consuming low throughput method. Simpler methods such as Tanaka's scheme are preferred. In the present work, the Abraham's model is revisited to develop a fast and reliable method, similar to the one proposed by Tanaka, for the characterization of columns employed in reversed-phase liquid chromatography and particularly in hydrophilic interaction liquid chromatography. For this purpose, pairs of compounds are carefully selected in order to have in common all molecular descriptors except for a specific one (for instance, similar molecular volume, dipolarity, polarizability, and hydrogen bonding basicity features, but different hydrogen bonding acidity). Thus, the selectivity factor of a single pair of test compounds can provide information regarding the extent of the dissimilar solute-solvent interactions and their influence on chromatographic retention. The proposed characterization method includes the determination of the column hold-up volume and Abraham's cavity term by means of the injection of four alkyl ketone homologues. Therefore, five chromatographic runs in a reversed-phase column (four pairs of test solutes and a mixture of four homologues) are enough to characterize the selectivity of a chromatographic system. Tanaka's method is also analyzed from the LSER point of view.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.aca.2023.341672-
dc.relation.ispartofAnalytica Chimica Acta, 2023, vol. 1277, p. 341672-
dc.relation.urihttps://doi.org/10.1016/j.aca.2023.341672-
dc.rightscc-by-nc-nd (c) Redón, Lídia, et al., 2023-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationSolvatació-
dc.subject.classificationCromatografia de líquids-
dc.subject.otherSolvation-
dc.subject.otherLiquid chromatography-
dc.titleCharacterization of solute-solvent interactions in liquid chromatography systems: A fast method based on Abraham's linear solvation energy relationships-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec738500-
dc.date.updated2023-09-20T15:04:14Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Institut de Biomedicina (IBUB))
Articles publicats en revistes (Enginyeria Química i Química Analítica)

Files in This Item:
File Description SizeFormat 
738500.pdf3.29 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons