Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/204328
Title: Diagnostic Accuracy of Abdominal CT for Locally Advanced Colon Tumors: Can We Really Entrust Certain Decisions to the Reliability of CT?
Author: García del Álamo Hernández, Yaiza
Cano Valderrama, Óscar
Cerdán Santacruz, Carlos
Pereira Pérez, Fernando
Aldrey Cao, Inés
Núñez Fernández, Sandra
Álvarez Sarrado, Eduardo
Obregón Reina, Rosángela
Dujovne Lindenbaum, Paula
Taboada Ameneiro, María
Ambrona Zafra, David
Pérez Farré, Silvia
Pascual Damieta, Marta
Frago Montanuy, Ricardo
Flor Lorente, Blas
Biondo, Sebastiano
Collaborative Group For The Study Of Metachronous Peritoneal Metastases Of Pt4 Colon Cancer
Keywords: Càncer colorectal
Tomografia
Colorectal cancer
Tomography
Issue Date: 26-Oct-2023
Publisher: MDPI AG
Abstract: Many different options of neoadjuvant treatments for advanced colon cancer are emerging. An accurate preoperative staging is crucial to select the most appropriate treatment option. A retrospective study was carried out on a national series of operated patients with T4 tumors. Considering the anatomo-pathological analysis of the surgical specimen as the gold standard, a diagnostic accuracy study was carried out on the variables T and N staging and the presence of peritoneal metastases (M1c). The parameters calculated were sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios, as well as the overall accuracy. A total of 50 centers participated in the study in which 1950 patients were analyzed. The sensitivity of CT for correct staging of T4 colon tumors was 57%. Regarding N staging, the overall accuracy was 63%, with a sensitivity of 64% and a specificity of 62%; however, the positive and negative likelihood ratios were 1.7 and 0.58, respectively. For the diagnosis of peritoneal metastases, the accuracy was 94.8%, with a sensitivity of 40% and specificity of 98%; in the case of peritoneal metastases, the positive and negative likelihood ratios were 24.4 and 0.61, respectively. The diagnostic accuracy of CT in the setting of advanced colon cancer still has some shortcomings for accurate diagnosis of stage T4, correct classification of lymph nodes, and preoperative detection of peritoneal metastases.
Note: Reproducció del document publicat a: https://doi.org/10.3390/jcm12216764
It is part of: Journal of Clinical Medicine, 2023, vol. 12, num. 21
URI: http://hdl.handle.net/2445/204328
Related resource: https://doi.org/10.3390/jcm12216764
ISSN: 2077-0383
Appears in Collections:Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
jcm-12-06764.pdf496.23 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons