Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/209247
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHachem, Abdul Ilah-
dc.contributor.authorMolina Creixell, Andrés-
dc.contributor.authorRondanelli S., Rafael-
dc.contributor.authorValero Cifuentes, Gregorio-
dc.contributor.authorCampagnoli, Alex-
dc.contributor.authorHermida, Miguel-
dc.contributor.authorRius, Xavier-
dc.date.accessioned2024-03-26T19:42:15Z-
dc.date.available2024-03-26T19:42:15Z-
dc.date.issued2023-09-01-
dc.identifier.issn2212-6287-
dc.identifier.urihttp://hdl.handle.net/2445/209247-
dc.description.abstractThe arthroscopic remplissage procedure has been described to successfully treat engaging Hill-Sachs lesions and improve shoulder stability. Several variations of this technique have been described, including remplissage with 1 or 2 knotted or knotless anchors, remplissage with double or triple bridging pulleys, and remplissage with or without a subacromial view. However, most techniques use anchors in combination with round sutures. This article describes an allarthroscopic articular knotless remplissage technique using a strong, flat, double-strand suture tape bridge fixed with 2 small anchors under direct joint visualization and reduction of the capsule and infraspinatus without requiring a subacromial view.-
dc.format.extent8 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier BV-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.eats.2023.04.021-
dc.relation.ispartofArthroscopy Techniques, 2023, vol. 12, num. 9, p. e1487-e1494-
dc.relation.urihttps://doi.org/10.1016/j.eats.2023.04.021-
dc.rightscc by-nc-nd (c) Hachem, Abdul Ilah et al., 2023-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))-
dc.subject.classificationLuxacions-
dc.subject.classificationHúmer-
dc.subject.classificationArtroscòpia-
dc.subject.otherDislocations-
dc.subject.otherHumerus-
dc.subject.otherArthroscopy-
dc.titleArthroscopic All-Inside Remplissage Technique With Knotless Tape Bridge for Hill-Sachs Lesions-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.date.updated2023-10-31T09:25:16Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid37780647-
Appears in Collections:Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
PIIS2212628723001299.pdf2.26 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons