Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/211084
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGuillem, Maria S.-
dc.contributor.authorPujol López, Margarida-
dc.contributor.authorSanchez Arciniegas, Jorge-
dc.contributor.authorMont Girbau, Lluís-
dc.date.accessioned2024-05-09T15:55:44Z-
dc.date.available2024-05-09T15:55:44Z-
dc.date.issued2023-03-08-
dc.identifier.issn1045-3873-
dc.identifier.urihttp://hdl.handle.net/2445/211084-
dc.description.abstractConduction system pacing (CSP) has emerged as an alternative treatment for patients with indication for cardiac resynchronization therapy (CRT). As opposed to biventricular CRT (BIV-CRT), which is based on left epicardial stimulation, CSP aims to restore the conduction through the His-Purkinje system pacing distally to level of block. Randomized evidence with His bundle pacing (HBP)(1–3) and left bundle branch pacing (LBBP)(4,5) is not extensive compared with the available BIV-CRT data. Non-inferiority of CSP as compared to BIV-CRT has been proven in a randomized trial (LEVEL-AT)(4); furthermore, the LBBP-RESYNC trial(5) has shown greater left ventricular (LV) ejection fraction improvement with LBBP versus BiV-CRT in non-ischemic patients with left bundle branch block (LBBB).-
dc.format.extent8 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherWiley-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1111/jce.15871-
dc.relation.ispartofJournal of Cardiovascular Electrophysiology, 2023, vol. 34, num.4, p. 994-996-
dc.relation.urihttps://doi.org/10.1111/jce.15871-
dc.rights(c) Wiley, 2023-
dc.sourceArticles publicats en revistes (Medicina)-
dc.subject.classificationDesfibril·ladors cardioversors implantables-
dc.subject.classificationMarcapassos-
dc.subject.classificationMedicina personalitzada-
dc.subject.classificationCor-
dc.subject.classificationInsuficiència cardíaca-
dc.subject.otherImplantable cardioverter-defibrillators-
dc.subject.otherCardiac pacemakers-
dc.subject.otherPersonalized medicine-
dc.subject.otherHeart-
dc.subject.otherHeart failure-
dc.titleIn silico experiments explain the non-consistent benefit of conduction system pacing over cardiac resynchronization therapy. The need to personalize therapy-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec744749-
dc.date.updated2024-05-07T15:21:08Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.idimarina9343520-
dc.identifier.pmid36852911-
Appears in Collections:Articles publicats en revistes (Medicina)
Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)

Files in This Item:
File Description SizeFormat 
848414.pdf1.05 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.