Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/214176
Title: HRFlexToT: A High Dynamic Range ASIC for Time-of-Flight Positron Emission Tomography
Author: Sánchez, David
Gómez, Sergio
Mauricio, J.
Freixas, Lluis
Sanuy, A.
Guixé, Gerard
López, Albert
Manera Escalero, R.
Marín, Jesús
Pérez, José.M.
Picatoste Olloqui, Eduardo
Pujol, Carolina
Sanmukh, A.
Rato, Pedro
Vela, Óscar
Gascón Fora, David
Keywords: Tomografia per emissió de positrons
Fotoelectroquímica
Positron emission tomography
Photoelectrochemistry
Issue Date: 1-Jan-2022
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
Abstract: Abstract: Time-of-Flight positron emission tomography scanners demand fast and efficient photo sensors and scintillators coupled to fast readout electronics. This article presents the high resolution flexible Time-over-Threshold (HRFlexToT), a 16-channel application-specific-integrated circuit for silicon photomultipliers (SiPM) anode readout manufactured using XFAB 0.18- μm CMOS technology. The main features of the HRFlexToT are a linear Time-over-Threshold with an extended dynamic range (10 bits) for energy measurement, low power consumption (≈ 3.5 mW/ch), and an excellent timing response. The experimental measurements show an energy linearity error of ≈ 3% and an energy resolution of about 12% at 511 keV. Single-photon time resolution measurements performed using an Fondazione Bruno Kessler (FBK) SiPM NUV-HD ( 4×4 mm2 pixel, 40- μm cell) and a Hamamatsu SiPM S13360-3050CS are around 142 and 167 ps full width at half maximum (FWHM), respectively. Coincidence time resolution (CTR) measurements with small cross-section pixelated crystals (LSO:Ce,Ca 0.4%, 2×2×5 mm3) coupled to the same Hamamatsu S13360-3050CS and FBK NUV-HD sensors yield a CTR of 117 ps and 119 ps, respectively. Measurements performed with a large cross-section monolithic crystal (LFS crystal measuring 25×25×20 mm3) and a Hamamatsu SiPM array S13361-6050NE-04 show a CTR of 324 ps FWHM after time-walk and time-skew correction.
Note: Versió postprint del document publicat a: https://doi.org/10.1109/TRPMS.2021.3066426
It is part of: IEEE Transactions on Radiation and Plasma Medical Sciences, 2022, vol. 6, num.1, p. 51-67
URI: https://hdl.handle.net/2445/214176
Related resource: https://doi.org/10.1109/TRPMS.2021.3066426
ISSN: 2469-7311
Appears in Collections:Articles publicats en revistes (Institut de Ciències del Cosmos (ICCUB))
Articles publicats en revistes (Física Quàntica i Astrofísica)

Files in This Item:
File Description SizeFormat 
255284.pdf2.98 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.