Title: Accuracy of standard bipolar amplitude voltage thresholds to identify late potential channels in ventricular tachycardia ablation
Author: Roca Luque, Ivo
Zaraket, Fatima
Garre Anguera de Sojo, Paz
Sánchez Somonte, Paula
Quinto, Levio
Borras, Roger
Guasch i Casany, Eduard
Arbelo, Elena
Tolosana, José M. (José María)
Brugada Terradellas, Josep, 1958-
Mont Girbau, Lluís
Keywords: Taquicàrdia
Ventricles cardíacs
Cicatrius
Malalties del cor
Tachycardia
Ventricle of heart
Scars
Heart diseases
Issue Date: 23-Feb-2022
Publisher: Springer Verlag
Abstract: Background: Ventricular tachycardia (VT) is caused by the presence of a slow conduction channel (CC) of border zone (BZ) tissue inside the scar-core tissue. Electroanatomic mapping can depict this tissue by voltage mapping. Areas of slow conduction can be detected as late potentials (LPs) and their abolition is the most accepted ablation endpoint. In the current guidelines, bipolar voltage thresholds for BZ and core scar are 1.5 and 0.5 mV respectively. The performance of these values is controversial. The aim of the study is to analyze the diagnostic yield of current amplitude thresholds in voltage map to define VT substrate in terms of CCs of LPs. Predictors of usefulness of current thresholds will be analyzed. Methods: All patients with structural heart disease who underwent VT ablation in Hospital Clinic in 2016-2017 were included. Maps with delineation of CCs based on LPs were created with contact force sensor catheter. Thresholds were adjusted for every patient based on CCs. Diagnostic yield and predictors of performance of conventional thresholds were analyzed. Results: During study period, 57 consecutive patients were included (age: 60.4 ± 8.5; 50.2% ischemic cardiomyopathy, LVEF 39.8 ± 13.5%). Cutoff voltages that better identified the scar and BZ according to the LP channels were 0.32 (0.02-2 mV) and 1.84 (0.3-6 mV) respectively. Current voltage thresholds identified correctly core and BZ in 87.7% and 42.1% of the patients respectively. Accuracy was worse in non-ischemic cardiomyopathy (NICM) especially for BZ (28.6% vs 55.2%, p = 0.042). Conclusions: Accuracy of standard voltage thresholds for scar and BZ is poor in terms of LPs detection. Diagnostic yield is worse in NICM patients specially for border zone.
Note: Reproducció del document publicat a: https://doi.org/10.1007/s10840-022-01148-6
It is part of: Journal of Interventional Cardiac Electrophysiology, 2023, vol. 66, num.1, p. 15-25
URI: http://hdl.handle.net/2445/214271
Related resource: https://doi.org/10.1007/s10840-022-01148-6
ISSN: 1383-875X
Appears in Collections:Articles publicats en revistes (Medicina)
Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)

Files in This Item:
File Description SizeFormat 
249295.pdf1.3 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons