Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/216551
Title: Use of metal oxide semiconductor sensors to measure methane in aquatic ecosystems in the presence of cross-interfering compounds
Author: Butturini, Andrea
Fonollosa Magrinyà, Jordi
Keywords: Metà
Ecologia aquàtica
Metall-òxid-semiconductors
Methane
Aquatic ecology
Metal oxide semiconductors
Issue Date: Nov-2022
Publisher: Association for the Sciences of Limnology and Oceanography
Abstract: Monitoring dissolved methane in aquatic ecosystems contributes significantly to advancing our understanding of the carbon cycle in these habitats and capturing their impact on methane emissions. Low-cost metal oxide semiconductors (MOS) gas sensors are becoming an increasingly attractive tool to perform such measurements, especially at the air-water interface. However, the performance of MOS sensors in aquatic environmental sciences has come under scrutiny because of their cross-sensitivity to temperature, moisture, and sulfide interference. In this study, we evaluated the performance and limitations of a MOS methane sensor when measuring dissolved methane in waters. A MOS sensor was encapsulated in a hydrophobic extended polytetrafluoroethylene membrane to impede contact with water but allow gas perfusion. Therefore, the membrane enabled us to submerge the sensor in water and overcome cross-sensitivity to humidity. A simple portable, low-energy, flow-through cell system was assembled that included an encapsulated MOS sensor and a temperature sensor. Waters (with or without methane) were injected into the flow cell at a constant rate by a peristaltic pump. The signals from the two sensors were recorded continuously with a cost-efficient microcontroller. Tests specifically focused on the effect of water temperature and sulfide interference on sensor performance. Our experiments revealed that the lower limit of the sensor was in the range of 0.1-0.2 μmol L−1 and that it provided a stable response at water temperatures in the range of 18.5-28°C. Dissolved sulfide at a concentration of 0.4 mmol L−1 or higher interfered with the sensor response, especially at low methane concentrations (0.5 μmol L−1 or lower). However, we show that if dissolved sulfide is monitored, its interference can be alleviated.
Note: Reproducció del document publicat a: https://doi.org/10.1002/lom3.10515
It is part of: Limnology and Oceanography: Methods, 2022, vol. 20, num.11, p. 710-720
URI: https://hdl.handle.net/2445/216551
Related resource: https://doi.org/10.1002/lom3.10515
ISSN: 1541-5856
Appears in Collections:Articles publicats en revistes (Biologia Evolutiva, Ecologia i Ciències Ambientals)

Files in This Item:
File Description SizeFormat 
258213.pdf1.19 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons