Por favor, use este identificador para citar o enlazar este documento:
https://hdl.handle.net/2445/218746
Título: | in vivo Monitoring with micro-implantable hypoxia sensor based on tissue acidosis |
Autor: | Dulay, Samuel Rivas, Lourdes Miserere, Sandrine Pla, Laura Berdún, Sergio Parra, Johanna Eixarch Roca, Elisenda Gratacós Solsona, Eduard Illa, Míriam Mir Llorente, Mònica Samitier i Martí, Josep |
Materia: | Acidosi Isquèmia Electroquímica Acidosis Ischemia Electrochemistry |
Fecha de publicación: | 1-may-2021 |
Publicado por: | Elsevier B.V. |
Resumen: | Hypoxia is a common medical problem, sometimes difficult to detect and caused by different situations. Control of hypoxia is of great medical importance and early detection is essential to prevent life threatening complications. However, the few current methods are invasive, expensive, and risky. Thus, the development of reliable and accurate sensors for the continuous monitoring of hypoxia is of vital importance for clinical monitoring. Herein, we report an implantable sensor to address these needs. The developed device is a low-cost, miniaturised implantable electrochemical sensor for monitoring hypoxia in tissue by means of pH detection. This technology is based on protonation/deprotonation of polypyrrole conductive polymer. The sensor was optimized in vitro and tested in vivo intramuscularly and ex vivo in blood in adult rabbits with respiration-induced hypoxia and correlated with the standard device ePOCTM. The sensor demonstrated excellent sensitivity and reproducibility; 46.4 ± 0.4 mV/pH in the pH range of 4–9 and the selectivity coefficient exhibited low interference activity in vitro. The device was linear (R2 = 0.925) with a low dispersion of the values (n = 11) with a cut-off of 7.1 for hypoxia in vivo and ex vivo. Statistics with one-way ANOVA (α = 0.05), shows statistical differences between hypoxia and normoxia states and the good performance of the pH sensor, which demonstrated good agreement with the standard device. The sensor was stable and functional after 18 months. The excellent results demonstrated the feasibility of the sensors in real-time monitoring of intramuscular tissue and blood for medical applications. |
Nota: | Versió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2020.122045 |
Es parte de: | Talanta, 2021, vol. 226 |
URI: | https://hdl.handle.net/2445/218746 |
Recurso relacionado: | https://doi.org/10.1016/j.talanta.2020.122045 |
ISSN: | 0039-9140 |
Aparece en las colecciones: | Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) Articles publicats en revistes (Institut de Bioenginyeria de Catalunya (IBEC)) Articles publicats en revistes (BCNatal Fetal Medicine Research Center) Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer) |
Archivos de este documento:
Archivo | Descripción | Dimensiones | Formato | |
---|---|---|---|---|
247630.pdf | 756.77 kB | Adobe PDF | Mostrar/Abrir |
Este documento está sujeto a una
Licencia Creative Commons