Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/219577
Title: Magnetic resonance imaging in patients with cardiac implantable electronic devices: the RESONANCE Spanish registry
Author: Ruiz Mateas, Francisco
Pérez, Marcos Antonio
García López, Fernando
González, Susana
Anguera Camós, Ignasi
Gusi Tragant, Gabriel
Robledo Irrañitu, María
Fernández Lozano, Ignacio
Martínez, Juan Gabriel
Alzueta Rodríguez, Francisco Javier
Keywords: Imatges per ressonància magnètica
Marcapassos
Magnetic resonance imaging
Cardiac pacemakers
Issue Date: 1-Nov-2024
Publisher: Oxford University Press (OUP)
Abstract: Aims: Despite increasing evidence demonstrating the safety of magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs), this procedure is often neglected in this population. This Spanish registry aimed to determine the proportion of MRI referrals and performance among patients with pacemakers (PMs) or implantable cardioverter defibrillators (ICDs). Methods and results: This prospective, multicentre, open-label registry involved 21 Spanish centres. Data were collected upon implant of PMs or ICDs from BIOTRONIK and one year after, and included the number of MRIs and computed tomography scans prescribed, performed and denied, and reasons for denial. Data from 1105 patients (mean age: 74.2 years) were analysed and 982 completed the follow-up. Of them, 82.2% had a PM and 17.8% an ICD. A total of 351 imaging tests were prescribed in 220 patients (19.9%), including 52 MRIs in 39 patients (3.5%) and 299 computed tomography scans in 196 patients (17.8%). Among the MRIs, 44 (84.6%) were performed, five (9.6%) were not performed, and three (5.8%) were replaced by an alternative test. Most of the indicated computed tomography scans were performed (97.7%). The proportion of patients with an MRI scan referral was 4.6% during the pre-COVID-19 period and 2.6% during the COVID-19 period. No MRI-related arrhythmic ventricular event was reported. Conclusion: This registry revealed that only 3.5% of patients with CIEDs had an MRI referral over the study, with rates decreasing to 2.6% during the COVID-19 period. These rates contrast with the 85 MRIs conducted per 1000 inhabitants in Spain in 2020.
Note: Reproducció del document publicat a: https://doi.org/10.1093/europace/euae277
It is part of: Europace, 2024, vol. 26, num. 11
URI: https://hdl.handle.net/2445/219577
Related resource: https://doi.org/10.1093/europace/euae277
ISSN: 1532-2092
Appears in Collections:Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
euae277.pdf697.51 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons