Please use this identifier to cite or link to this item:
https://hdl.handle.net/2445/219969
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Mallafré Muro, Celia | - |
dc.contributor.author | Cruz, Meryl | - |
dc.contributor.author | Blanco i Borrego, Arnau | - |
dc.contributor.author | Fernández Romero, Lluís | - |
dc.contributor.author | Pardo Martínez, Antonio | - |
dc.contributor.author | Marco Colás, Santiago | - |
dc.date.accessioned | 2025-03-25T09:55:12Z | - |
dc.date.available | 2025-03-25T09:55:12Z | - |
dc.date.issued | 2022-06-10 | - |
dc.identifier.uri | https://hdl.handle.net/2445/219969 | - |
dc.description.abstract | GC-IMS is a very good complementary technique to traditional GC-MS, that presents some advantages, but also, some disadvantages such as misalignments produced by many parameters affecting the equipment stability. The reproducibility of the measures has been studied in two different measurement campaigns with a set of automatized quality control parameters. Figures of merit from one region of interest present in the samples show that the saturation and asymmetry do not change between measurement campaigns, but the volume and area of the total ion spectra change. A correction of these changes between batches should be developed. | - |
dc.format.extent | 4 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | IEEE | - |
dc.relation.isformatof | Versió postprint del document publicat a: https://doi.org/10.1109/ISOEN54820.2022.9789683 | - |
dc.relation.ispartof | Comunicació a: 2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN), International Society for Olfaction and Chemical Sensing (ISOCS), Aveiro, Portugal, 29 de maig - 1 de juny 2022 | - |
dc.relation.uri | https://doi.org/10.1109/ISOEN54820.2022.9789683 | - |
dc.rights | (c) IEEE, 2022 | - |
dc.source | Comunicacions a congressos (Enginyeria Electrònica i Biomèdica) | - |
dc.subject.classification | Visualització | - |
dc.subject.classification | Mesurament de superfícies | - |
dc.subject.classification | Control de qualitat | - |
dc.subject.other | Visualization | - |
dc.subject.other | Area measurement | - |
dc.subject.other | Quality control | - |
dc.title | Study of quality controls for stability check of the ROIs of a ketones mixture in different GC-IMS measurement campaigns | - |
dc.type | info:eu-repo/semantics/conferenceObject | - |
dc.type | info:eu-repo/semantics/acceptedVersion | - |
dc.identifier.idgrec | 483643 | - |
dc.date.updated | 2025-03-18T12:34:36Z | - |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
dc.identifier.idimarina | 6572620 | - |
dc.identifier.idsira | 739952 | - |
Appears in Collections: | Comunicacions a congressos (Enginyeria Electrònica i Biomèdica) Comunicacions a congressos (Institut de Bioenginyeria de Catalunya (IBEC)) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2022_ISOEN_Study_MarcoS_Postprint.pdf | 677.39 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.