Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/220053
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMuñoz Mahamud, Ernesto-
dc.contributor.authorChimeno, Clara-
dc.contributor.authorFernández-Valencia, J. A. (Jenaro-Ángel)-
dc.contributor.authorAlías, Alfonso-
dc.contributor.authorSerra, Adrià-
dc.contributor.authorPostnikov, Yury-
dc.contributor.authorCombalía Aleu, Andrés-
dc.date.accessioned2025-03-27T08:10:52Z-
dc.date.available2025-03-27T08:10:52Z-
dc.date.issued2023-05-15-
dc.identifier.issn0341-2695-
dc.identifier.urihttps://hdl.handle.net/2445/220053-
dc.description.abstractPurpose: Failure to restore the femoral offset of the native hip is a potential cause of dysfunctional hip arthroplasty. The aim of this study was to report our experience of using a modular head-neck adapter in revision THA, specifically analyzing its usefulness as a tool to correct a slightly diminished femoral offset. Materials and methods: This was a retrospective single-center study including all hip revisions performed at our institution from January 2017 to March 2022 where the BioBallTM head-neck metal adapter was used. The preoperative and one year follow-up modified Merle d'Aubigné hip score was used to evaluate functional outcomes. Results: Of a total of 34 cases included for revision, the head-neck adapter system was used specifically in six patients (17.6%) to increase femoral offset, retaining both the acetabular and femoral components. In this subgroup of patients, mean offset decrease after primary THA was 6.6 mm (4.0-9.1), equivalent to a mean 16.3% femoral offset reduction. The median modified Merle d'Aubigné score went from 13.3 preoperatively to 16.2 at one year follow-up. Conclusion: The use of a head-neck adapter is a safe and reliable procedure that may allow the surgeon to easily correct a slightly diminished femoral offset in a dysfunctional THA without the need to revise well-fixed prosthetic components.-
dc.format.extent7 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherSpringer Verlag-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1007/s00264-023-05833-7-
dc.relation.ispartofInternational Orthopaedics, 2023, vol. 47, p. 2245-2251-
dc.relation.urihttps://doi.org/10.1007/s00264-023-05833-7-
dc.rightscc by (c) Muñoz Mahamud, Ernesto et al., 2023-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)-
dc.subject.classificationCirurgia ortopèdica-
dc.subject.classificationTraumatologia-
dc.subject.classificationCirurgia dels ossos-
dc.subject.otherOrthopedic surgery-
dc.subject.otherTraumatology-
dc.subject.otherSurgery of bones-
dc.titleContribution of the BioballTM head-neck adapter to the restoration of femoral offset in hip revision arthroplasty with retention of a well-fixed cup and stem-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec738671-
dc.date.updated2025-03-27T08:10:52Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid37188902-
Appears in Collections:Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)

Files in This Item:
File Description SizeFormat 
826407.pdf777.27 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons