Please use this identifier to cite or link to this item:
https://hdl.handle.net/2445/220585
Title: | The on-ground data reduction and calibration pipeline for SO/PHI-HRT |
Author: | Sinjan, Jonas Calchetti, D. Hirzberger, Johann Orozco Suarez, David Kinga, Albert Albelo, Jorge Nestor Appourchaux, Thierry Alvarez-Herrero, Alberto Blanco Rodriguez, Julian Gandorfer Achim, M. Germerott, Dietmar Guerrero, Lucas Marquez, Pablo Gutierrez Kahil, Fatima Kolleck, M. Solanki, S. K. del Toro Iniesta, Jose Carlos Volkmer, Reiner Woch, J. Fiethe, B. Gómez Cama, José María Pérez-Grande, I. Sanchis Kilders, E. Balaguer Jiménez, M. Bellot Rubio, L.R. Carmona Flores, Manuel Deutsch, W. Fernandez-Rico, G. Fernandez-Medina, Ana B. García Parejo, P. Gasent Blesa, José L. Gizon, L. Grauf, B. Heerlein, K. Korpi-Lagg, A. Lange, T. López Jiménez, A. Maue, Thorsten Meller, R. Michalik, Harald Moreno Vacas, A. Müller, R. Nakai, Eiji Schmidt, Wolfgang Schou, J. Schühle, U. Staub, J. Strecker, H. Torralbo, I. Valori, G. |
Keywords: | Astrofísica Heliosismologia Astrophysics Helioseismology |
Issue Date: | 1-Jan-2022 |
Publisher: | Society of Photo-Optical Instrumentation Engineers (SPIE) |
Abstract: | The ESA/NASA Solar Orbiter space mission has been successfully launched in February 2020. Onboard is the Polarimetric and Helioseismic Imager (SO/PHI), which has two telescopes, a High Resolution Telescope (HRT) and the Full Disc Telescope (FDT). The instrument is designed to infer the photospheric magnetic field and line-of-sight velocity through differential imaging of the polarised light emitted by the Sun. It calculates the full Stokes vector at 6 wavelength positions at the Fe I 617.3 nm absorption line. Due to telemetry constraints, the instrument nominally processes these Stokes profiles onboard, however when telemetry is available, the raw images are downlinked and reduced on ground. Here the architecture of the on-ground pipeline for HRT is presented, which also offers additional corrections not currently available on board the instrument. The pipeline can reduce raw images to the full Stokes vector with a polarimetric sensitivity of 10−3⋅Ic or better. |
Note: | Reproducció del document publicat a: https://doi.org/10.1117/12.2629323 |
It is part of: | Proceedings of SPIE, 2022, vol. 12189 |
URI: | https://hdl.handle.net/2445/220585 |
Related resource: | https://doi.org/10.1117/12.2629323 |
ISSN: | 0277-786X |
Appears in Collections: | Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
865024.pdf | 10.98 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.