dc.description.abstractWhen planning for epilepsy surgery, multiple potential sites for resection may be identified through anatomical imaging. Magnetoencephalography (MEG) using optically pumped sensors (OP-MEG) is a non-invasive functional neuroimaging technique which could be used to help identify the epileptogenic zone from these candidate regions. Here we test the utility of a-priori information from anatomical imaging for differentiating potential lesion sites with OP-MEG. We investigate a number of scenarios: whether to use rigid or flexible sensor arrays, with or without a-priori source information and with or without source modelling errors. We simulated OP-MEG recordings for 1309 potential lesion sites identified from anatomical images in the Multi-centre Epilepsy Lesion Detection (MELD) project. To localise the simulated data, we used three source inversion schemes: unconstrained, prior source locations at centre of the candidate sites, and prior source locations within a volume around the lesion location. We found that prior knowledge of the candidate lesion zones made the inversion robust to errors in sensor gain, orientation and even location. When the reconstruction was too highly restricted and the source assumptions were inaccurate, the utility of this a-priori information was undermined. Overall, we found that constraining the reconstruction to the region including and around the participant's potential lesion sites provided the best compromise of robustness against modelling or measurement error.-
dc.format.extent12 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherNature Publishing Group-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1038/s41598-024-51857-3-
dc.relation.ispartofScientific Reports, 2024, vol. 14, num.1-
dc.relation.urihttps://doi.org/10.1038/s41598-024-51857-3-
dc.rightscc-by (c) Pascual, Lluis Saul et al., 2024-
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.sourceArticles publicats en revistes (Fonaments Clínics)-
dc.subject.classificationSimulació (Ciències de la salut)-
dc.subject.classificationCirurgia-
dc.subject.classificationEpilèpsia-
dc.subject.otherMalingering-
dc.subject.otherSurgery-
dc.subject.otherEpilepsy-
dc.titleCombining OPM and lesion mapping data for epilepsy surgery planning: a simulation study-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec756752-
dc.date.updated2025-06-12T10:55:33Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid38311614-
Appears in Collections:Articles publicats en revistes (Fonaments Clínics)

Files in This Item:
File Description SizeFormat 
887368.pdf4.19 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons