Please use this identifier to cite or link to this item:
https://hdl.handle.net/2445/222058
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rodríguez, Daniel | - |
dc.contributor.author | Carnaval, Thiago | - |
dc.contributor.author | Rodríguez Chaves, Marcos del Carmen | - |
dc.contributor.author | Coscujuela i Mañá, Antoni | - |
dc.contributor.author | Agullo, Jose Luis | - |
dc.contributor.author | Videla Ces, Sebastià | - |
dc.date.accessioned | 2025-07-07T16:50:21Z | - |
dc.date.available | 2025-07-07T16:50:21Z | - |
dc.date.issued | 2025-05-09 | - |
dc.identifier.uri | https://hdl.handle.net/2445/222058 | - |
dc.description.abstract | This case series reports the only 3 instances of ceramic liner breakage among patients who underwent total hip arthroplasty (THA) with polyethylene-ceramic composite (sandwich-type) liners at our center between 1999 and 2002. Breakages occurred at approximately 6 (n = 2) and 17 years (n = 1) after the primary THA. Symptoms included audible crepitation, pain, and restricted motion during normal activities. Surgical revisions utilized a polyethylene liner and third-generation alumina ceramic head, with synovectomy and irrigation to remove debris (preventing third-body wear). All patients achieved good long-term outcomes. Although infrequent, the risk of breakage increases over time, and several patients still carry these liners years after THA. This case series underscores the importance of vigilant follow-up, patient education, and timely intervention to manage this infrequent but potentially catastrophic complication. | - |
dc.format.extent | 6 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier Inc. | - |
dc.relation.isformatof | Reproducció del document publicat a: https://doi.org/https://doi.org/10.1016/j.artd.2025.101698 | - |
dc.relation.ispartof | Arthroplasty Today, 2025, vol. 33 | - |
dc.relation.uri | https://doi.org/10.1016/j.artd.2025.101698 | - |
dc.rights | cc-by (c) Rodríguez, D. et al., 2025 | - |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | - |
dc.source | Articles publicats en revistes (Patologia i Terapèutica Experimental) | - |
dc.subject.classification | Polietilè | - |
dc.subject.classification | Artroplàstia | - |
dc.subject.classification | Cirurgia ortopèdica | - |
dc.subject.other | Polyethylene | - |
dc.subject.other | Arthroplasty | - |
dc.subject.other | Orthopedic surgery | - |
dc.title | Management and outcomes of breakage in polyethylene-ceramic composite (Sandwich-type) liners: lessons from long-term follow-up | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | info:eu-repo/semantics/publishedVersion | - |
dc.identifier.idgrec | 758477 | - |
dc.date.updated | 2025-07-07T16:50:21Z | - |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
dc.identifier.pmid | 40475005 | - |
Appears in Collections: | Articles publicats en revistes (Patologia i Terapèutica Experimental) Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL)) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
893701.pdf | 831.64 kB | Adobe PDF | View/Open |
This item is licensed under a
Creative Commons License